Development Assessment Panel

 

Business Paper

 

date of meeting:

 

Wednesday 9 May 2018

location:

 

Function Room

Port Macquarie-Hastings Council

17 Burrawan Street

Port Macquarie

time:

 

2:00pm

 


Development Assessment Panel

 

CHARTER

 


 

 

1.0     OBJECTIVES

 

To assist in managing Council's development assessment function by providing independent and expert determinations of development applications that fall outside of staff delegations.

 

 

2.0     KEY FUNCTIONS

 

·                To review development application reports and conditions;

·                To determine development  applications  outside  of staff delegations;

·                To  refer development  applications to  Council for  determination  where necessary;

·                To provide a forum for objectors and applicants to make submissions on applications before  the Development Assessment Panel (DAP);

·                To maintain transparency in the determination of development applications.

 

Delegated Authority of Panel

 

Pursuant to Section 377 of the Local Government Act, 1993 delegation to:

·                Determine development applications under Part 4 of the Environmental Planning and Assessment Act 1979 having regard to the relevant environmental planning instruments, development control plans and Council policies.

·                Vary, modify or release restrictions as to use and/or covenants created by Section 88B instruments under the Conveyancing Act 1919 in relation to development applications for subdivisions being considered by the panel.

·                Determine Koala Plans of Management under State Environmental Planning Policy 44 - Koala Habitat Protection associated with development applications being considered by the Panel.

 

Noting the trigger to escalate decision making to Council as highlighted in section 5.2.

 

 

3.0      MEMBERSHIP

 

3.1      Voting Members

 

·                Two independent external members. One of the independent external members to be the Chairperson.

·                Group Manager Development Assessment (alternate - Director Development & Environment or Development Assessment Planner)

 

The independent external members shall have expertise in one or more of the following areas: planning, architecture, heritage, the environment, urban design, economics, traffic and transport, law, engineering, government and public administration.

 

3.2      Non-Voting Members

 

·                Not applicable

3.3      Obligations of members

 

·                Members must act faithfully and diligently and in accordance with    this Charter.

·                Members must comply with Council's Code of Conduct.

·                Except as required to properly perform their duties, DAP members must not disclose any confidential information (as advised by Council) obtained in connection with the DAP functions.

·                Members will have read and be familiar with the documents and information provided by Council prior to attending a DAP                                              meeting.

·                Members must act in accordance with Council's Workplace Health and Safety Policies and Procedures

·                External members of the Panel are not authorised to speak to the media on behalf of Council. Council officers that are members of the Committee are bound by the existing operational delegations in relation to speaking to the media.

·                Staff members shall not vote on matters before the Panel if they have been the principle author of the development assessment report.

 

3.4      Member Tenure

 

·                The independent external members will be appointed for the term of four (4) years maximum in which the end of the tenure of these members would occur in a cascading arrangement.

 

3.5      Appointment of members

 

·                The independent external members (including the Chair) shall be appointed by the General Manager following an external Expression of Interest process.

·                Staff members of the Panel are in accordance with this Charter.

 

 

4.0     TIMETABLE OF MEETINGS

 

·                The Development Assessment Panel will generally meet on the 1st and 3rd Wednesday each month at 2.00pm at the Port Macquarie offices of Council.

·                Special Meetings of the Panel may be convened by the Director Development & Environment Services with three (3) days notice.

 

 

5.0      MEETING PRACTICES

 

5.1      Meeting Format

 

·                At all Meetings of the Panel the Chairperson shall occupy the Chair and preside. The Chair will be responsible for keeping of order at meetings.

·                Meetings shall be open to the   public.

·                The Panel will hear from applicants and objectors or their r e p r e s e n t a t i v e s .

·                Where considered necessary, the Panel will conduct site inspections which will be open to the public.

 

5.2      Decision Making

 

·                Decisions are to be made by consensus. Where consensus is not possible on any item, that item is to be referred to Council for a decision.

·                All development applications involving a proposed variation to a development standard greater than 10% under Clause 4.6 of the Local Environmental Plan will be considered by the Panel and recommendation made to the Council for a decision.

 

5.3      Quorum

 

·                All members (2 independent external members and 1 staff member) must be present at a meeting to form a quorum.

 

5.4      Chairperson and Deputy Chairperson

 

·                Independent Chair (alternate, second independent member)

 

5.5     Secretariat

 

·                The Director Development &n Environment is to be responsible for ensuring that the Panel has adequate secretariat support. The secretariat will ensure that the business paper and supporting papers are circulated at least three (3) days prior to each meeting. Minutes shall be appropriately approved and circulated to each member within three (3) weeks of a meeting being held.

·                The format of and the preparation and publishing of the Business Paper and Minutes shall be similar to the format for Ordinary Council Meetings.

 

5.6      Recording of decisions

 

·                Minutes will record decisions and how each member votes for each item before the Panel.

 

 

6.0     CONVENING OF “OUTCOME SPECIFIC” WORKING GROUPS

 

Not applicable.

 

 

7.0     CONFIDENTIALITY AND CONFLICT OF INTEREST

 

·                Members of the Panel must comply with the applicable provisions of Council’s Code of Conduct. It is the personal responsibility of members to comply with the standards in the Code of Conduct and regularly review their personal circumstances with this in mind.

·                Panel members must declare any conflict of interests at the start of each meeting or before discussion of a relevant item or topic. Details of any conflicts of interest should be appropriately minuted. Where members are deemed to have a real or perceived conflict of interest, it may be appropriate they be excused from deliberations on the issue where the conflict of interest may exist. A Panel meeting may be postponed where there is no quorum.

 

 

8.0     LOBBYING

 

·                All members and applicants are to adhere to Council’s Lobbying policy. Outside of scheduled Development Assessment Panel meetings, applicants, their representatives, Councillors, Council staff and the general public are not to lobby Panel members via meetings, telephone conversations, correspondence and the like. Adequate opportunity will be provided at Panel inspections or meetings for applicants, their representatives and the general public to make verbal submissions in relation to Business Paper items.


Development Assessment Panel

 

ATTENDANCE REGISTER

 

 

 

Member

28/02/18

14/03/18

28/03/18

11/04/18

26/04/18

Paul Drake

P

P

P

P

P

Robert Hussey

       A

A

P

P

P

David Crofts

(alternate member)

P

P

 

 

 

Dan Croft

(Acting Director Development & Environment)

Clinton Tink

(Acting GM Development Assessment

(alternates)

- Director Development & Environment

- Development Assessment Planner

 

P

 

 

P

 

 

P

 

 

P

P

 

P

 

Key: P =  Present

         A  =  Absent With Apology

         =  Absent Without Apology

 

 

 


Development Assessment Panel Meeting

Wednesday 9 May 2018

 

Items of Business

 

 

Item       Subject                                                                                                      Page

 

01           Acknowledgement of Country............................................................................ 8

02           Apologies......................................................................................................... 8

03           Confirmation of Minutes.................................................................................... 8

04           Disclosures of Interest..................................................................................... 15

05           DA2017 - 780.1 Shop Top Housing - Lot 1 DP 536032, No. 4 Hastings River Drive, Port Macquarie....................................................................................................... 19

06           Section 4.55 Modification DA2010 - 577.4 - Modification To Subdivision Lot Layout Including Addition Of One (1) Torrens Title Lot - Lot 2 DP 1231106, No. 72 Lorne Road, Kendall    91  

07           General Business

 


AGENDA                                              Development Assessment Panel      09/05/2018

Item:          01

Subject:     ACKNOWLEDGEMENT OF COUNTRY

 

"I acknowledge that we are gathered on Birpai Land. I pay respect to the Birpai Elders both past and present. I also extend that respect to all other Aboriginal and Torres Strait Islander people present."

 

 

Item:          02

Subject:     APOLOGIES

 

RECOMMENDATION

That the apologies received be accepted.

 

 

Item:          03

Subject:     CONFIRMATION OF PREVIOUS MINUTES

Recommendation

That the Minutes of the Development Assessment Panel Meeting held on 26 April 2018 be confirmed.

 


MINUTES

Development Assessment Panel Meeting

                                                                                                                                  26/04/2018

 

 

 

 

PRESENT

 

Members:

Paul Drake

Robert Hussey

Clinton Tink

 

Other Attendees:

Dan Croft

Ben Roberts

Chris Gardiner

Grant Burge

 

The meeting opened at 2.10pm.

 

 

01       ACKNOWLEDGEMENT OF COUNTRY

The Acknowledgement of Country was delivered.

 

 

02       APOLOGIES

Nil.

 

 

03       CONFIRMATION OF MINUTES

CONSENSUS:

 

That the Minutes of the Development Assessment Panel Meeting held on 11 April 2018 be confirmed, subject to an amendment to the Consensus on Item 06, as tabled by Robert Hussey and seconded by Paul Drake as follows:

 

The panel was unable to reach a consensus.

 

For: Paul Drake and Clinton Tink

 

That DA2018 – 48.1 for demolition of existing structures and erection of emergency services facility (ambulance station) and lot consolidation at Lot 26 & 27, DP 37531, No. 94 - 96 High Street, Wauchope, be determined by granting consent subject to the recommended conditions as amended in accordance with the agreement of the applicant:

 

Add Condition D(10) to state:

 

D(10)   Prior to occupation, a 1.5m high solid screen is to be erected along the outer edge kerb of the western exit driveway, commencing at the edge of the building and ceasing at the point, where the driveway changes and starts to narrow. The screen is to minimise vehicle headlight glare impacting on the adjoining neighbour to the west.

 

Robert Hussey disagreed with the majority decision for the following reasons:

 

  1. The application should be approved subject to a Deferred Commencement condition requiring the provision of a gravity disposal system for the stormwater, via a downstream easement, instead of the proposed mechanical pump-out system, particularly considering the lack of any Council Policy on mechanical pump outs.
  2. The visual impact of the bulk and scale of the skillion roof, which could be reduced on the southern elevation.

 

The above amended minutes are to clarify that while a consensus was still not reached, Robert Hussey did not recommend refusal but rather disagreed with the majority decision.

 

 

04      DISCLOSURES OF INTEREST

 

There were no disclosures of interest presented.

 

 

05       DA2017 - 1023.1 Agricultural Produce Industry Lot 4 DP 738164, No 511 FernbaNk Creek Road, Fernbank Creek

Speakers:

Debra King (objector)

Gary Cuttell (applicant)

 

CONSENSUS:

 

That DA 2017 – 1023.1 for agricultural produce industry (apple cider) at Lot 4 DP 738164 No. 511 Fernbank Creek Road, Fernbank Creek, be determined by granting consent subject to the recommended conditions as amended:

 

Add condition B(5) to state:

 

B(5)     Prior to release of the Construction Certificate, a waste management plan dealing with waste water and solid waste, is to be submitted to Council for approval.

 

 

06       Section 4.55 Modification DA2010 - 577.4 - Modification To Subdivision Lot Layout Including Addition Of One (1) Torrens Title Lot - Lot 2 DP 1231106, No. 72 Lorne Road, Kendall

Speakers:

Geraldine Haigh (applicant)

 

CONSENSUS:

 

Defer determination of the Section 4.55 modification to DA 2010 – 577, subject to the submission of stormwater management detail being provided to the Development Assessment Panel. The information is to show how stormwater impacts on the new Lot 8 and also whether the new Lot 8 impacts on the ability to deal with stormwater management for the overall subdivision.

 

 

07       DA2017 - 1125.1 Two Lot Subdivision and Erection of Four Semi-Detached Dwellings with Strata Subdivision and Two Jetties - Lot 1 DP 833585, 78 Commodore Crescent, Port Macquarie

Speakers:

Ian Little (objector)

Andrew Dickson (applicant)

 

CONSENSUS:

 

That DA 2017 - 1125 for a two lot subdivision and erection of four semi-detached dwellings with strata subdivision and two jetties at Lot 1, DP 833585, No. 78 Commodore Crescent, Port Macquarie, be determined by granting consent subject to the recommended conditions.

 

 

08       DA2018 - 75.1 Two (2) Semi-Detached Dwellings At Lot 132 DP 1229250, 11 Sandy Shores Avenue, Lake Cathie.

Speakers:

Pat Innes (objector)

James Collins (applicant)

 

CONSENSUS:

 

That DA 2018 - 75.1 for two semi-detached dwellings at Lot 132, DP 1229250, No. 11 Sandy Shores Avenue, Lake Cathie, be determined by granting consent subject to the recommended conditions as amended:

 

Amend condition B(11) to state:

 

B(11)   (B072) A stormwater drainage design is to be submitted and approved by Council prior to the issue of a Construction Certificate. The design must be prepared in accordance with Council’s AUSPEC Specifications and the requirements of Relevant Australian Standards and make provision for the following:

a)    The legal point of discharge for the proposed development is defined as the kerb and gutter of a public road.

b)    All allotments must be provided with a direct point of connection to the public piped drainage system. Kerb outlets are not permitted.

c)    The design requires the provision of interallotment drainage in accordance with AUSPEC D5.

d)    The design shall include water quality controls designed to achieve the targets specified within AUSPEC D7.

e)    The design is to make provision for the natural flow of stormwater runoff from uphill/upstream properties/lands. The design must include the collection of such waters and discharge to the Council drainage system.

 

 

09       DA2017 - 1110.1 Demolition Of Dwelling And Construction Of New Dwelling - Lot 27 DP 20480, No. 24 Bundella Avenue, Lake Cathie

Speakers:

Nigel Swift (applicant)

 

CONSENSUS:

 

That DA 2017 – 1110.1 for demolition of dwelling and construction of a new dwelling at Lot 27, DP 20480, No. 24 Bundella Avenue, Lake Cathie, be determined by granting consent subject to the recommended conditions.

 

 

10       DA2017 - 1084.1 Clubhouse - Lot 7054 DP 1074173, No. 12 Maritime Lane (Oxley Oval), Port Macquarie

Speakers:

Chris King (objector)

David Brown (objector)

Teale Bryan (applicant)

 

CONSENSUS:

 

That it be recommended to Council that DA 2017 – 1084.1 for a clubhouse at Lot 7054, DP 1074173, No. 12 Maritime Lane (Oxley Oval), Port Macquarie, be determined by granting consent subject to the recommended conditions.

 

 

11       DA2017 - 1138.1 Dwelling And Secondary Dwelling At Lot 61 DP 1226839, No. 33 Summer Circuit, Lake Cathie

Speakers:

Derek Collins (applicant)

 

CONSENSUS:

 

That DA 2017 – 1138.1 for a dwelling and secondary dwelling at Lot 61, DP 1226839, No. 33 Summer Circuit, Lake Cathie, be determined by granting consent subject to the recommended conditions.

 

 

12       Section 4.55 Modification DA2004 - 687.5 To Modify The Hours Of Operation For Existing Sawmill At Lot 1 DP 1065577, Old Kempsey Road, Gum Scrub

Speakers:

Gaylene Codd (objector)

Kerry Graham (objector)

David Bell (objector)

Pat Kinnarney (objector)

Sandra Ozolins (objector)

Andrew Lister (applicant)

Noel Atkins (applicant)

Daryl Hayden (applicant)

 

CONSENSUS:

 

That the section 4.55 modification to DA 2004 – 687.5 for a modification of hours of operation of an existing sawmill at Lot 1, DP 1065577, No. 269 Old Kempsey Rd, Gum Scrub, be determined by granting consent subject to the recommended conditions as amended

 

Add condition A(17) to state:

 

A(17) Within three (3) months of the date of determination of modification five (5), a maintenance operating plan detailing the types of maintenance activities to occur onsite, is to be submitted to Council for approval (Note: the date of determination of modification five (5) is to be 26 April 2018 and the three (3) month due date will be 26 July 2018).

 

Amend condition F(9) to state:

 

F(9) (DDOCC00630) Hours of operation of the development are restricted the following times:

a)    Sawmill: 7am-6pm Monday to Friday

b)    General Maintenance: 6pm-9pm Monday to Friday and 8am-6pm Sundays.

No logging truck movements are permitted during general maintenance hours and there is to be no work on Saturdays or Public Holidays.

 

The above amended times are approved for a trial period of twelve (12) months from the date of determination of modification five (5). Upon expiration of the twelve (12) month trial period, the hours of operation are to revert back to the previous approved hours of operation, unless a further modification is submitted and approved. A complaints register is also to be kept and detail any associated actions taken to rectify issues raised. The complaints register is to be provided to Council at the end of the twelve (12) month trial period. It should be noted that the date of determination of modification five (5) is to be 26 April 2018 and the twelve (12) month trial period for the amended hours of operation will cease on 26 April 2019.

 

 

13       DA2018 - 74.1 Dwelling - Lot 2 DP 1237933, No 122B Camden Head Road, Dunbogan

Emails from Bronwyn and Roy Davies (objector) were tabled for consideration.

 

Speakers:

Nigel Swift (applicant)

 

CONSENSUS:

 

That DA 2018- 74.1 for a dwelling at Lot 2, DP1237933, No. 122B Camden Head Road, Dunbogan be determined by granting consent subject to the recommended conditions.

 

 

14       GENERAL BUSINESS

Nil.

 

 

 

 

The meeting closed at 4.30pm.

 

 

 

 

 


AGENDA                                              Development Assessment Panel      09/05/2018

Item:          04

Subject:     DISCLOSURES OF INTEREST

 

RECOMMENDATION

 

That Disclosures of Interest be presented

 

DISCLOSURE OF INTEREST DECLARATION

 

 

Name of Meeting:     ………………………………………………………………………..

 

Meeting Date:           ………………………………………………………………………..

 

Item Number:            ………………………………………………………………………..

 

Subject:                      ………………………………………………………………………..

                                    …………………………………………………….……………...…..

 

 

I, ..................................................................................... declare the following interest:

 

 

        Pecuniary:

              Take no part in the consideration and voting and be out of sight of the meeting.

 

 

        Non-Pecuniary - Significant Interest:

              Take no part in the consideration and voting and be out of sight of the meeting.

 

        Non-Pecuniary - Less than Significant Interest:

              May participate in consideration and voting.

 

 

For the reason that:  ....................................................................................................

 

.......................................................................................................................................

 

Name:  …………………………………………………….

 

Signed:  .........................................................................  Date:  ..................................

 

 

Growth Bar b&w(Further explanation is provided on the next page)


 

Further Explanation

(Local Government Act and Code of Conduct)

 

A conflict of interest exists where a reasonable and informed person would perceive that a Council official could be influenced by a private interest when carrying out their public duty. Interests can be of two types: pecuniary or non-pecuniary.

 

All interests, whether pecuniary or non-pecuniary are required to be fully disclosed and in writing.

 

Pecuniary Interest

 

A pecuniary interest is an interest that a Council official has in a matter because of a reasonable likelihood or expectation of appreciable financial gain or loss to the Council official. (section 442)

 

A Council official will also be taken to have a pecuniary interest in a matter if that Council official’s spouse or de facto partner or a relative of the Council official or a partner or employer of the Council official, or a company or other body of which the Council official, or a nominee, partner or employer of the Council official is a member, has a pecuniary interest in the matter. (section 443)

 

The Council official must not take part in the consideration or voting on the matter and leave and be out of sight of the meeting.  The Council official must not be present at, or  in sight of, the meeting of the Council at any time during which the matter is being considered or discussed, or at any time during which the council is voting on any question in relation to the matter.  (section 451)

 

Non-Pecuniary

 

A non-pecuniary interest is an interest that is private or personal that the Council official has that does not amount to a pecuniary interest as defined in the Act.

 

Non-pecuniary interests commonly arise out of family, or personal relationships, or involvement in sporting, social or other cultural groups and associations and may include an interest of a financial nature.

 

The political views of a Councillor do not constitute a private interest.

 

The management of a non-pecuniary interest will depend on whether or not it is significant.

 

Non Pecuniary – Significant Interest

As a general rule, a non-pecuniary conflict of interest will be significant where a matter does not raise a pecuniary interest, but it involves:

(a)   A relationship between a Council official and another person that is particularly close, for example, parent, grandparent, brother, sister, uncle, aunt, nephew, niece, lineal descendant or adopted child of the Council official or of the Council official’s spouse, current or former spouse or partner, de facto or other person living in the same household.

(b)   Other relationships that are particularly close, such as friendships and business relationships. Closeness is defined by the nature of the friendship or business relationship, the frequency of contact and the duration of the friendship or relationship.

(c)   An affiliation between a Council official an organisation, sporting body, club, corporation or association that is particularly strong.

 

If a Council official declares a non-pecuniary significant interest it must be managed in one of two ways:

1.     Remove the source of the conflict, by relinquishing or divesting the interest that creates the conflict, or reallocating the conflicting duties to another Council official.

2.     Have no involvement in the matter, by taking no part in the consideration or voting on the matter and leave and be out of sight of the meeting, as if the provisions in section 451(2) apply.

 

Non Pecuniary – Less than Significant Interest

If a Council official has declared a non-pecuniary less than significant interest and it does not require further action, they must provide an explanation of why they consider that the conflict does not require further action in the circumstances.

SPECIAL DISCLOSURE OF PECUNIARY INTEREST DECLARATION

 

 

By

[insert full name of councillor]

 

 

In the matter of

[insert name of environmental planning instrument]

 

 

Which is to be considered at a meeting of the

[insert name of meeting]

 

 

Held on

[insert date of meeting]

 

 

PECUNIARY INTEREST

 

 

Address of land in which councillor or an  associated person, company or body has a proprietary interest (the identified land)i

 

 

Relationship of identified land to councillor

[Tick or cross one box.]

 

Councillor has interest in the land (e.g. is owner or has other interest arising out of a mortgage, lease trust, option or contract, or otherwise).

 

Associated person of councillor has interest in the land.

 

Associated company or body of councillor has interest in the land.

 

MATTER GIVING RISE TO PECUNIARY INTEREST

 

 

Nature of land that is subject to a change

in zone/planning control by proposed

LEP (the subject land iii

[Tick or cross one box]

 

The identified land.

 

Land that adjoins or is adjacent to or is in proximity to the identified land.

Current zone/planning control

[Insert name of current planning instrument and identify relevant zone/planning control applying to the subject land]

 

Proposed change of zone/planning control

[Insert name of proposed LEP and identify proposed change of zone/planning control applying to the subject land]

 

Effect of proposed change of zone/planning control on councillor

[Tick or cross one box]

 

Appreciable financial gain.

 

Appreciable financial loss.

 

 

 

Councillor’s Name:  …………………………………………

 

Councillor’s Signature:  ……………………………….   Date:  ………………..


 

 

Important Information

 

This information is being collected for the purpose of making a special disclosure of pecuniary interests under sections 451 (4) and (5) of the Local Government Act 1993.  You must not make a special disclosure that you know or ought reasonably to know is false or misleading in a material particular.  Complaints made about contraventions of these requirements may be referred by the Director-General to the Local Government Pecuniary Interest and Disciplinary Tribunal.

 

This form must be completed by you before the commencement of the council or council committee meeting in respect of which the special disclosure is being made.   The completed form must be tabled at the meeting.  Everyone is entitled to inspect it.  The special disclosure must be recorded in the minutes of the meeting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

i.   Section 443 (1) of the Local Government Act 1993 provides that you may have a pecuniary interest in a matter because of the pecuniary interest of your spouse or your de facto partner or your relativeiv or because your business partner or employer has a pecuniary interest. You may also have a pecuniary interest in a matter because you, your nominee, your business partner or your employer is a member of a company or other body that has a pecuniary interest in the matter.

ii.  Section 442 of the Local Government Act 1993 provides that a pecuniary interest is an interest that a person has in a matter because of a reasonable likelihood or expectation of appreciable financial gain or loss to the person. A person does not have a pecuniary interest in a matter if the interest is so remote or insignificant that it could not reasonably be regarded as likely to influence any decision the person might make in relation to the matter or if the interest is of a kind specified in section 448 of that Act (for example, an interest as an elector or as a ratepayer or person liable to pay a charge).

iii.   A pecuniary interest may arise by way of a change of permissible use of land adjoining, adjacent to or in proximity to land in which a councillor or a person, company or body referred to in section 443 (1) (b) or (c) of the Local Government Act 1993 has a proprietary interest..

iv.   Relative is defined by the Local Government Act 1993 as meaning your, your spouse’s or your de facto partner’s parent, grandparent, brother, sister, uncle, aunt, nephew, niece, lineal descendant or adopted child and the spouse or de facto partner of any of those persons.

 

 

 


AGENDA                                              Development Assessment Panel      09/05/2018

 

 

Item:          05

 

Subject:     DA2017 - 780.1 Shop Top Housing - Lot 1 DP 536032, No. 4 Hastings River Drive, Port Macquarie

Report Author: Fiona Tierney

 

 

 

Applicant:               Wayne Ellis Architect

Owner:                    Gerranne Pty Ltd

Estimated Cost:     $3,800,000

Parcel no:               8383

Alignment with Delivery Program

4.3.1 Undertake transparent and efficient development assessment in accordance with relevant legislation.

 

 

 

 

RECOMMENDATION

That DA 2017 – 380.1 for shop top housing at Lot 1, DP 536032, No. 4 Hastings River Drive, Port Macquarie, be determined by granting consent subject to the recommended conditions.

 

Executive Summary

 

This report considers a development application for a shop top housing at the subject site and provides an assessment of the application in accordance with the Environmental Planning and Assessment Act 1979.

The application was previously reported to the Development Assessment Panel on 28th February 2018 at which the consensus was as follows:

 

CONSENSUS:

That DA2017 – 780.1 be deferred to allow the applicant to address the deficiency in parking and how it can be accommodated either onsite or in the area.

 

The applicant has addressed the concerns raised and submitted revised plans for consideration.

 

 

1.       BACKGROUND

 

Existing sites features and surrounding development

 

The site has an area of 1081m².

 

The site is zoned B2 Local Centre in accordance with the Port Macquarie-Hastings Local Environmental Plan 2011, as shown in the following zoning plan:

 

http://pmhq-v-gtx01.pmhc.nsw.gov.au/Geocortex/Essentials/GXE471/REST/TempFiles/EBP%20Layout.jpg?guid=253cf330-1386-440d-a832-b4fc8725b8c7&contentType=image%2Fjpeg

The existing subdivision pattern and location of existing development within the locality is shown in the following aerial photograph:

 

http://pmhq-v-gtx01.pmhc.nsw.gov.au/Geocortex/Essentials/GXE471/REST/TempFiles/EBP%20Layout.jpg?guid=1e1c0b46-1c16-4844-add4-80fc74e990ea&contentType=image%2Fjpeg

2.       DESCRIPTION OF DEVELOPMENT

 

Key aspects of the proposal include the following:

 

 

·    Four storey shop top housing with commercial floor space at ground level

·    Ground floor car parking

·    Twelve (12) x two (2) bedroom units and five (5) x one (1) bedroom units

 

Refer to attachments at the end of this report.

 

Application Chronology

 

·    4 April 2017 - Pre-lodgement meeting

·    4 September 2017 - Application Lodged

·    15 to 28 September 2017 - Neighbour notification

·    15 September 2017 - Heritage advisor comments

·    28 February 2018 – Application appeared before the Development Assessment Panel and application deferred to receive additional information relating to parking

·    13 March 2018 - Additional information received

 

3.       STATUTORY ASSESSMENT

 

Section 79C(1) Matters for Consideration

 

In determining the application, Council is required to take into consideration the following matters as are relevant to the development that apply to the land to which the development application relates:

 

(a)     The provisions (where applicable) of:

(i)      any Environmental Planning Instrument:

 

State Environmental Planning Policy No.55 – Remediation of Land

Following an inspection of the site and a search of Council records, the subject land is not identified as being potentially contaminated and is suitable for the intended use.

 

State Environmental Planning Policy No. 62 – Sustainable Aquaculture

Given the nature of the proposed development and proposed stormwater controls the proposal will be unlikely to have any adverse impact on existing aquaculture industries within the Hastings River.

 

State Environmental Planning Policy No. 64 – Advertising and Signage

There is no signage proposed as part of the application. Suitable condition has been recommended advising of consent requirements for future signage.

 

State Environmental Planning Policy 65 - Design Quality of Residential Apartment Development

In accordance with clause 4, the subject SEPP applies to the proposal. It is noted that no Design Review Panel has been appointed by Port Macquarie-Hastings Council following amendments to this Policy in July 2015.

In accordance with clause 30(2), the proposal has demonstrated satisfactory consideration against the design quality principles contained in the Apartment Design Guide and the following table provides an assessment against these principles:

 

Requirement

Proposed

Complies

Principle 1:Context & Neighbourhood Character

Good design responds and contributes to its context. Context is the key natural and built features of an area, their relationship and the character they create when combined. It also includes social, economic, health and environmental conditions.

Health and environmental conditions.

Responding to context involves identifying the desirable elements of an area’s existing or future character.

Well-designed buildings respond to and enhance the qualities and identity of the area including the adjacent sites, streetscape and neighbourhood. Consideration of local context is important for all sites, including sites in established areas, those undergoing change or identified for change.

The proposal is for a four storey shop top housing development. The area is characterised by a mixture of commercial, tourist and higher density developments. The area is currently undergoing rapid redevelopment with a number of higher density flat buildings, shop top housing and medical developments underway or proposed in the immediate area. Encouraging higher density in areas with close proximity to the CBD or business zones is desirable.

The proposed building design is compatible with existing development and the desired future character of the area as stated in the relevant planning and design policies. It is considered the building will contribute to the identity of the area.

Yes

Principle 2:Built form and Scale

Good design achieves a scale, bulk and height appropriate to the existing or desired future character of the street and surrounding buildings. Good design also achieves an appropriate built form for a site and the building’s purpose in terms of building alignments, proportions, building type, articulation and the manipulation of building elements. Appropriate built form defines the public domain, contributes to the character of streetscapes and parks, including their views and vistas, and provides internal amenity and outlook.

 

The height and bulk of the proposed building is considered to be acceptable in the streetscape and future desired character of the area.

The building is considered to achieve an appropriate built form and incorporates interesting building elements and treatments that will complement the streetscape.

The proposed internal unit layouts provide for internal amenity. The orientation of the block takes advantage of the northern outlook.

Yes

Principle 3:Density

Good design achieves a high level of amenity for residents and each apartment, resulting in a density appropriate to the site and its context. Appropriate densities are consistent with the area’s existing or projected population. Appropriate densities can be sustained by existing or proposed infrastructure, public transport, access to jobs, community facilities and the environment.

 

 

The proposal is for a floor space ratio (FSR) of approximately 1.21:1, which complies with the maximum 1.8:1 FSR adopted in the LEP.

The adopted FSR for the site is consistent with the objectives of the B2 zone and the height of buildings envisaged for the area.

The proposed density is also considered to be sustainable having regard to availability of infrastructure and public transport, proximity to services/community facilities and the environmental quality of the area.

Yes

Principle 4:Sustainability

Good design combines positive environmental, social and economic outcomes. Good sustainable design includes use of natural cross ventilation and sunlight for the amenity and liveability of residents and passive thermal design for ventilation, heating and cooling reducing reliance on technology and operation costs. Other elements include recycling and reuse of materials and waste, use of sustainable materials, and deep soil zones for groundwater recharge and vegetation.

 

Most units contain a suitable level of north/north east facing balconies/aspect and opportunities for solar access and natural ventilation.

A BASIX certificate has been provided demonstrating that the design satisfies acceptable energy and water efficiency measures.

 

Yes

Principle 5:Landscape

Good design recognises that together landscape and buildings operate as an integrated and sustainable system, resulting in attractive developments with good amenity. A positive image and contextual fit of well-designed developments is achieved by contributing to the landscape character of the streetscape and neighbourhood. Good landscape design enhances the development’s environmental performance by retaining positive natural features which contribute to the local context, co-ordinating water and soil management, solar access, micro-climate, tree canopy, habitat values, and preserving green networks. Good landscape design optimises usability, privacy and opportunities for social interaction, equitable access, respect for neighbours’ amenity, provides for practical establishment and long term management.

 

Satisfactory landscaping. The soil depth and area available is consistent the Apartment Design Guide and provides for a variety of landscaping that incorporates medium sized trees and lower scale plantings that is considered acceptable for the site.

 

Yes

Principle 6:Amenity

Good design positively influences internal and external amenity for residents and neighbours. Achieving good amenity contributes to positive living environments and resident well-being. Good amenity combines appropriate room dimensions and shapes, access to sunlight, natural ventilation, outlook, visual and acoustic privacy, storage, indoor and outdoor space, efficient layouts and service areas, and ease of access for all age groups and degrees of mobility.

 

Adequate storage and outdoor space provided throughout the building.

Accessibility is possible via ramps, stairs and lifts.

The layout of the units has taken advantage of the north/eastern orientation with an emphasis of natural sunlight and ventilation via predominantly north facing windows and balconies and access to external common areas.

The design and layout will provide a good level of amenity.

All units are accessible via a lift.

Building depth is satisfactory.

All units include a sufficient amount of private open space.

Communal open space is satisfactory.

Yes

Principle 7:Safety

Good design optimises safety and security, within the development and the public domain. It provides for quality public and private spaces that are clearly defined and fit for the intended purpose. Opportunities to maximise passive surveillance of public and communal areas promote safety. A positive relationship between public and private spaces is achieved through clearly defined secure access points and well lit and visible areas that are easily maintained and appropriate to the location and purpose.

 

The various array of windows, doors and balconies throughout the building provide surveillance of the site and also the public domain.

The proposal adequately addresses the principles of Crime Prevention Through Environmental Design.

 

Yes

Principle 8:Housing Diversity and Social Interaction

Good design achieves a mix of apartment sizes, providing housing choice for different demographics, living needs and household budgets. Well-designed apartment developments respond to social context by providing housing and facilities to suit the existing and future social mix. Good design involves practical and flexible features, including different types of communal spaces for a broad range of people, providing opportunities for social interaction amongst residents.

 

The proposal provides 12 x 2 bedroom apartments and 5 x 1 bedroom. The units will suit a variety of budgets and housing needs.

The proposal adequately addresses social requirements and housing affordability.

Yes

Principle 9:Aesthetics

Good design achieves a built form that has good proportions and a balanced composition of elements, reflecting the internal layout and structure. Good design uses a variety of materials, colours and textures. The visual appearance of well-designed apartment development responds to the existing or future local context, particularly desirable elements and repetitions of the streetscape.

 

The plans provide examples of the colours, textures and finishes.

The colours and materials provided on the plans indicate a contemporary high quality design and finish. It is considered that the aesthetics of the building will respond appropriately to the surrounding environment and context of the existing and desired character of the locality.

Yes

Clause 28(2), the proposal has adequately addressed the Apartment Design Guide. The following table provides an assessment against the relevant Apartment Design Guide criteria:

 

Requirement

Proposed

Complies

3A site analysis

Site analysis illustrates that design decisions have been based on opportunities and constraints of the site conditions and their relationship to the surrounding context.

Suitable site analysis provided.

Yes

3B orientation

Building types and layouts respond to the streetscape and site while optimising solar access within the development.

Ground floor commercial space with pedestrian and driveway entries respond to street.

Suitable solar access is available to the individual units throughout the year.

Overshadowing has been minimised to southern neighbours through increased setbacks to the southern boundary.

Yes

Overshadowing of neighbouring properties is minimised during mid-winter

 

Due to the orientation of the site the primary overshadowing impacts shall occur over the southern property. The development has been located to be sympathetic to this site with driveways located on the southern side to increase solar access. The southern property has their access via this northern side and is largely shaded by vegetation during the winter months. Balconies and living areas on the adjoining property are located to the south, which limits the overshadowing impacts to key north facing living areas. The proposal achieves compliance with sunlight criteria in that these areas will receive the minimum 3 hours direct sunlight between 9am and 3pm mid-winter.

Yes

3C public domain interface

Transition between private and public domain is achieved without compromising safety and security

Overlooking of street available form front living areas and entry is well lit and activated.

Yes

Amenity of the public domain is retained and enhanced.

 

Street frontage is activated through setback to Hastings River Drive with ground floor commercial tenancies and landscaping. Landscaping has been incorporated into the design to soften the built form.

Mailbox location acceptable.

Substations, pump rooms, garbage storage areas and other service requirements will be located in the car park/out of view.

Ramping for accessibility has been minimised by building entry locations and setting ground floor levels in relation to footpath levels.

Yes

3D Communal and public open space

Communal open space 25% of the site.

276m² of area available for use, which exceeds 25%.

Yes

50% direct sunlight to useable communal open space for 2 hours mid-winter

>50% direct sunlight to communal open space area.

Yes

Communal open space is designed to allow a range of activities, respond to site conditions and be attractive and inviting.

 

The communal area is considered to allow for a range of activities for both the individual and groups in a user friendly and northerly orientated open space. More specific landscape details will be required prior to issue of a Construction Certificate.

Yes

Communal open space is designed to maximise safety.

The communal open space is directly accessible from the stairway and designed to maximise safety. Communal open space and the public domain should be readily visible from habitable rooms and private open space areas while maintaining visual privacy.

Yes

Public open space, where provided, is responsive to the existing pattern and uses of the neighbourhood.

No public open space proposed.

N/A

3E deep soil zones

3m minimum dimensions required for deep soil zone and minimum 7% of site area.

1. Deep soil zones are to meet the following minimum requirements:

a)   < 650m², no min dimension, 7% site area deep soil zone.

b)   650-1500m², 3m dimension, 7% site area deep soil zone.

c)   >1500m², 6m dimension, 7% site area deep soil zone.

On some sites it may be possible to provide larger deep soil zones, depending on the site area and context:

-     10% of the site as deep soil on sites with an area of 650m² - 1,500m²

-     15% of the site as deep soil on sites greater than 1,500m².

Deep soil zones should be located to retain existing significant trees and to allow for the development of healthy root systems, providing anchorage and stability for mature trees. Design solutions may include:

-     basement and sub basement car park design that is consolidated beneath building footprints

-     use of increased front and side setbacks

-     adequate clearance around trees to ensure long term health

-     co-location with other deep soil areas on adjacent sites to create larger contiguous areas of deep soil.

Achieving the design criteria may not be possible on some sites including where:

-     the location and building typology have limited or no space for deep soil at ground level (e.g. central business district, constrained sites, high density areas, or in centres)

-     there is 100% site coverage or non-residential uses at ground floor level.

Where a proposal does not achieve deep soil requirements, acceptable stormwater management should be achieved and alternative forms of planting provided such as on structure.

Site is 1081m².

Deep soil planting proposed. A total of 228m² has been nominated as deep soil, which equates to 21% of the site.

Yes

3F visual privacy

Between habitable rooms and site boundaries:

- 6m separation up to 4 storeys

- 9m separation 5 and 6 storey

- 3m separation non habitable up to 4 storeys

- 4.5m separation non habitable up to 4 storeys

Does not comply with setback specifications but alternative walls and screens have been utilised to maximise privacy. Considered satisfactorily addressed.

No, but acceptable.

Site and building design elements increase privacy without compromising access to light and air and balance outlook and views from habitable rooms and private open space.

Natural screen wall plantings provide visual privacy without detrimentally impacting solar access and views.

Yes

3G Pedestrian access and entries

Building entries and pedestrian access connects to and addresses the public domain.

Multiple building entries are provided to ensure an activated street frontage is provided. Each access is clearly defined and articulated to the street.

Yes

Access, entries and pathways are accessible and easy to identify

 

The building access areas are clearly visible from the street and the ground floor is provided at grade in compliance with the relevant disability standards.

Yes

Large sites provide pedestrian links for access to streets and connection to destinations

 

Pedestrian connections to the public footpath running along Hastings River Drive are proposed in accordance with the design criteria.

Yes

3H Vehicle Access

Vehicle access points are designed and located to achieve safety, minimise conflicts between pedestrians and vehicles and create high quality streetscapes. Car park access should be integrated with the building’s overall facade. Design solutions may include:

-     the materials and colour palette to minimise visibility from the street

-     security doors or gates at entries that minimise voids in the facade

-     where doors are not provided, the visible interior reflects the facade design and the building services, pipes and ducts are concealed.

Car park entries should be located behind the building line.

Vehicle entries should be located at the lowest point of the site minimising ramp lengths, excavation and impacts on the building form and layout.

Car park entry and access should be located on secondary streets or lanes where available.

Vehicle standing areas that increase driveway width and encroach into setbacks should be avoided.

Access point locations should avoid headlight glare to habitable rooms.

Adequate separation distances should be provided between vehicle entries and street intersections.

The width and number of vehicle access points should be limited to the minimum.

Visual impact of long driveways should be minimised through changing alignments and screen planting.

The need for large vehicles to enter or turn around within the site should be avoided.

Garbage collection, loading and servicing areas are screened.

Clear sight lines should be provided at pedestrian and vehicle crossings.

Traffic calming devices such as changes in paving material or textures should be used where appropriate.

Pedestrian and vehicle access should be separated and distinguishable. Design solutions may include:

-     changes in surface materials

-     level changes

the use of landscaping for separation

The driveway entry is located via Hastings River Drive east of the site. Car park access satisfactorily integrated with the building’s overall facades.

Car park entry located behind the building line.

Vehicle entry located at the lowest point of the site minimising ramp lengths, excavation and impacts on the building form and layout.

Access point location avoids headlight glare to habitable rooms.

The width of the vehicle access point is limited.

Garbage collection, loading and servicing areas are screened.

Considered acceptable.

Yes

3J Bicycle and carparking

On land within 400m of B3 or B4 mixed use or equivalent in a nominated regional centre the min. car parking requirements set out in the Guide to Traffic Generating Developments are to be provided. the minimum car parking requirement for residents and visitors is set out in the Guide to Traffic Generating Developments, or the car parking requirement prescribed by the relevant council, whichever is less

The car parking needs for a development must be provided off street.

Where a car share scheme operates locally, provide car share parking spaces within the development. Car share spaces, when provided, should be on site.

Where less car parking is provided in a development, council should not provide on street resident parking permits

Guide to Traffic Generating Developments

Medium density residential flat buildings require:

-     1 space per unit +

-     1 space for every 5 x 2 bedroom unit +

-     1 space for every 2 x 3 bedroom unit +

-     1 space for 5 units (visitor parking).

High density residential flat buildings for metropolitan sub-regional centres require:

-   0.6 spaces per 1 bedroom unit

-   0.9 spaces per 2 bedroom unit

-   1.40 spaces per 3 bedroom unit +

1 space per 5 units (visitor parking)

Alternate parking calculation does not apply (ie the site is not located within 400m of a B3 or B4 zone). Utilise DCP rates, which are addressed later in this report.

 

Car share or parking permits not utilised or available.

N/A

Parking and facilities are provided for other modes of transport

Site is centrally located within short walk of all facilities. The basement car park allows for vehicle spaces to be used for motorbikes etc. There are also storage areas available for bicycles

Yes

Carpark design and access is safe and secure

Safe and secure parking proposed.

Yes

Visual and environmental impacts of underground car parking are minimised

The proposed basement car park shall not be visible from the street.

Yes

4A Solar and daylight access

Living rooms and private open space areas of at least 70% apartments receive 3 hours of sunlight mid-winter

Max. 15% of apartments receive no direct sunlight in mid-winter

Proposed development provides suitable sunlight. All units have multiple aspects over multiple levels with a northern aspect meaning all units will achieve 3 hours sunlight midwinter.

Yes

Daylight access is maximised where sunlight is limited

 

It is considered that adequate daylight access is available to each of the proposed units due to their orientation.

Yes

Design incorporates shading and glare control, particularly for warmer months

Proposed development provides suitable shading.

Yes

4B natural ventilation

All habitable rooms are naturally ventilated.

The building's orientation maximises capture and use of prevailing breezes for natural ventilation in habitable rooms.

Depths of habitable rooms support natural ventilation.

The area of unobstructed window openings should be equal to at least 5% of the floor area served.

Light wells are not the primary air source for habitable rooms.

Doors and openable windows maximise natural ventilation opportunities by using the following design solutions:

-    adjustable windows with large effective openable areas

-    a variety of window types that provide safety and flexibility such as awnings and louvres

windows which the occupants can reconfigure to funnel breezes into the apartment such as vertical louvres, casement windows and externally opening doors

The depths of the proposed unit’s habitable rooms are considered to support natural ventilation with suitable opportunities for cross ventilation due to multiple aspects.

Yes

The layout and design of single aspect apartments maximises natural ventilation.

No single aspect units.

Yes

60% of apartments are naturally cross ventilated

Cross ventilation provided.

 

Yes

Overall depth of crossover or cross through apartments does not exceed 18m

Proposal complies with width. Overall depth of cross-over or cross-through apartments do not exceed 18m, measured glass line to glass line.

The building includes several dual aspect apartments, cross through apartments and corner apartments and limited apartment depths.

Yes

 

4C ceiling heights

2.7m habitable rooms ceiling height

Proposal complies.

Units generally have minimum 2.8m ceiling heights. Small area to rear of upper unit 17 is 2.559m due to skillion roof slope.

Yes

Ceiling height increases the sense of space in apartments and provides for well-proportioned rooms

Acceptable.

 

Yes

Ceiling heights contribute to the flexibility of building use over the life of the building

Acceptable.

 

 

Yes

4D apartment size and layout

Apartment size minimums to be comply with:

Studio = 35m²

1 Bedroom = 50m²

2 Bedroom = 70m²

The minimum internal areas include only one bathroom. Additional bathrooms increase the minimum internal area by 5m² each.

A fourth bedroom and further additional bedrooms increase the minimum internal area by 12m² each.

2. Every habitable room must have a window in an external wall with a total minimum glass area of not less than 10% of the floor area of the room. Daylight and air may not be borrowed from other rooms.

Kitchens should not be located as part of the main circulation space in larger apartments (such as hallway or entry space).

A window should be visible from any point in a habitable room.

Where minimum areas or room dimensions are not met apartments need to demonstrate that they are well designed and demonstrate the usability and functionality of the space with realistically scaled furniture layouts and circulation areas. These circumstances would be assessed on their merits

Apartment size minimums comply with the exception of unit 8. However, it is considered the northern orientation and balcony area/layout will provide sufficient amenity and provides for a variety of housing.

Every habitable room has access to a window with compliant glass area.

Kitchens are not part of hallways etc.

No - however considered acceptable

Windows in habitable rooms with 10% of floor area

Windows provided and sufficient size.

Yes

Environmental performance of the apartment is maximised

Design Criteria

1. Habitable room depths are limited to a maximum of 2.5 x the ceiling height.

2. In open plan layouts (where the living, dining and kitchen are combined) the maximum habitable room depth is 8m from a window.

Greater than minimum ceiling heights can allow for proportional increases in room depth up to the permitted maximum depths.

All living areas and bedrooms should be located on the external face of the building.

Where possible:

-     bathrooms and laundries should have an external openable window.

main living spaces should be oriented toward the primary outlook and aspect and away from noise sources

Habitable room depths do not exceed 2.5 x the ceiling height.

The open plan areas do not exceed 8m.

Living areas and bedrooms are located on the external face of the building.

Proposed design considered compliant.

Yes

Apartment layouts are designed to accommodate a variety of household activities and needs

Design Criteria

1. Master bedrooms have a minimum area of 10m² and other bedrooms 9m² (excluding wardrobe space).

2. Bedrooms have a minimum dimension of 3m (excluding wardrobe space).

3. Living rooms or combined living/dining rooms have a minimum width of:

• 3.6m for studio and 1 bedroom apartments

• 4m for 2 and 3 bedroom apartments

4. The width of cross-over or cross-through apartments are at least 4m internally to avoid deep narrow apartment layouts.

Access to bedrooms, bathrooms and laundries is separated from living areas minimising direct openings between living and service areas.

All bedrooms allow a minimum length of 1.5m for robes.

The main bedroom of an apartment or a studio apartment should be provided with a wardrobe of a minimum 1.8m long, 0.6m deep and 2.1m high.

Apartment layouts allow flexibility over time, design solutions may include:

-     dimensions that facilitate a variety of furniture arrangements and removal

-     spaces for a range of activities and privacy levels between different spaces within the apartment

-     dual master apartments

-     dual key apartments Note: dual key apartments which are separate but on the same title are regarded as two sole occupancy units for the purposes of the Building Code of Australia and for calculating the mix of apartments

-     room sizes and proportions or open plans (rectangular spaces (2:3) are more easily furnished than square spaces (1:1))

efficient planning of circulation by stairs, corridors and through rooms to maximise the amount of usable floor space in rooms

Master bedrooms comply with the 10m² minimum standard and other bedrooms comply with the 9m² standard.

Bedrooms comply with 3m minimum dimension.

Living rooms comply with 4m minimum dimension.

Suitable separation of rooms exists via use of doors, walls etc

Robes in bedrooms considered acceptable.

Layouts contain flexibility.

The proposal for dual key apartments has been removed.

The lower door is to be removed and opening widened. Details are to be shown on the application for the construction certificate

Yes

4E Private open space and balconies

2 bed min area 10m² and min depth 2m

Balconies do not comply with the minimum depth requirement of 2m. Currently 1.8m.The consent is to be conditioned to require the plans to be amended to provide a 2m depth.

Yes

Ground floor min 15m² and min depth 3m

No residential units on ground floor.

N/A

Primary private open space and balconies are appropriately located to enhance liveability for residents.

The balconies for each of the proposed units are located off a bedroom and/or living area in a manner compliant with the design criteria.

Yes

Private open space and balcony design is integrated into and contributes to the overall architectural form and detail of the building.

The balcony design is considered to integrate into the architectural form of the building whilst providing views across the site, passive surveillance of the street and maintaining visual privacy for occupants.

Yes

Private open space and balcony design maximises safety.

 

Design is considered compliant however details of dividing screens to be detailed on plans. To be conditioned.

Changes in ground levels or landscaping are minimised.

Design and detailing of balconies avoids opportunities for climbing and falls subject to also complying with the Building Code of Australia. Specific details will be required to be provided and addressed prior to the issue of a construction certificate

Yes

4F Common circulation and spaces

Max. 8 units off a circulation core on a single level

Compliant

Yes

Common circulation spaces promote safety and provide for social interaction between residents

The proposed lift lobby will provide a short, direct entry to the lift with access to the units.

Direct and legible access is provided between vertical circulation points and apartment entries by minimising corridor or gallery length to give short, straight, clear sight lines.

Tight corners and spaces are avoided.

Circulation spaces are capable of being well lit at night and provided with appropriate signage.

Yes

4G Storage

a)   Min. storage requirements Studio apartments =  4m³.

b)   1 bedroom apartments =  6m³.

c)   2 bedroom apartments 8m³.

d)   3+ bedroom apartments = 10m³.

 At least 50% of the required storage is to be located within the apartment.

Storage is accessible from either circulation or living areas.

Suitable storage provided and additional in garage areas.

Yes

4H Acoustic privacy

Noise transfer is minimised through the siting of buildings and building layout

 

The use of separation, screening and having high use living areas face adjoining low use non habitable rooms (i.e. bathrooms) ensures no adverse acoustic issues. Living areas are also grouped throughout the levels of the building.

Other acoustic provisions of ADG have been suitably implemented.

Yes

Noise impacts are mitigated within apartments through layout and acoustic treatments.

 

Rooms with similar noise requirements are grouped together both internally within the apartments and between apartments. Internal walls between apartments shall be constructed so as to comply with the applicable noise and acoustic standards.

Yes

4J Noise and pollution

In noisy or hostile environments the impacts of external noise and pollution are minimised through the careful siting and layout of buildings.

The subject site is not considered to be located within a noisy or hostile environment.

N/A

Appropriate noise shielding or attenuation techniques for the building design, construction and choice of materials are used to mitigate noise transmission.

The building is to be designed using appropriate construction materials to comply with acceptable noise criteria. Condition to be applied to ensure compliance.

Yes

4K Apartment mix

A range of apartment types and sizes is provided to cater for different household types now and into the future.

 

The proposal is for a mixture of 1 & 2 bedroom units only. The mix is considered appropriate for the site and its position considering the distances to public transport, employment and education.

Yes

The apartment mix is distributed to suitable locations within the building.

Considered acceptable.

Yes

4L Ground floor apartments

Street frontage activity is maximised where ground floor apartments are located

No ground floor units proposed.

 

N/A

Design of ground floor apartments delivers amenity and safety for residents.

No ground floor units proposed.

 

N/A

4M Facades

Building facades provide visual interest along the street while respecting the character of the local area.

 

The proposed design provides a composition of varied building elements to ensure that the building is provided with variations in texture, material and detail. The proposal is considered compliant with the design criteria.

Yes

Building functions are expressed by the facade

The building entries are clearly defined from the street frontage via the provision of the access paths and variation of materials surrounding the entries. The proposal is considered compliant with the design criteria.

Yes

4N Roof design

Roof treatments are integrated into the building design and positively respond to the street.

Although not visible from the street the proposal is considered compliant with the design criteria.

Yes

Opportunities to use roof space for residential accommodation and open space are maximised

None proposed.

N/A

Roof design incorporates sustainability features

No roof space proposed

Yes

4O Landscape design

Landscape design is viable and sustainable

Suitable landscape plan provided that allows a range of plantings and potential for stormwater detention

Yes

Landscape design contributes to the streetscape and amenity

 

Suitable landscaping plan provided that will allow variation in species type and size conducive to the size of the development.

Yes

4P Planting on structures

Appropriate soil profiles are provided

 

The soil depth is considered capable of accommodating trees, shrubs, ground covers and turf. The proposal is considered compliant with the design criteria.

Yes

Plant growth is optimised with appropriate selection and maintenance

The plant species will be chosen for their suitability for the local environment and tolerance to the existing and proposed site conditions. The proposal is considered compliant with the design criteria.

Yes

Planting on structures contributes to the quality and amenity of communal and public open spaces

The proposal is considered compliant with the design criteria.

Yes

4Q Universal design

Universal design features are included in apartment design to promote flexible housing for all community members

 

Universal design features are included in apartment design to promote some flexible housing for all community members in particular units.

Yes

A variety of apartments with adaptable designs are provided

 

The proposed apartments are considered to provide a layout and design that caters for adaptable apartments which include a high level of solar access.

Yes

Apartment layouts are flexible and accommodate a range of lifestyle needs

 

The proposed apartments contain open plan living, kitchen and dining areas which are considered to be suitable for a variety of adaptable uses.

Yes

4S Mixed Use

Mixed use developments are provided in appropriate locations and provide active street frontages that encourage pedestrian movement

Commercial ground floor street activation and residential above.

 

Yes

Residential levels of the building are integrated within the development, and safety and amenity is maximised for residents

Separate access and parking areas well defined.

 

Yes

4T Awning and Signage

Awnings are well located and complement and integrate with the building design

 

Awnings are street aligned, well integrated into the building design and provide defined entry to commercial tenancy.

Yes

Signage responds to the context and desired streetscape character

To be proposed dependant on tenancy.

Yes

4U Energy efficiency

Development incorporates passive environmental design

 

The proposal is considered to provide adequate passive solar design. BASIX provided.

Yes

Development incorporates passive solar design to optimise heat storage in winter and reduce heat transfer in summer

The proposal is considered to provide adequate natural ventilation. BASIX provided.

Yes

Adequate natural ventilation minimises the need for mechanical ventilation

The proposal is considered to provide adequate natural ventilation. BASIX provided.

Yes

4V Water management and conservation

Potable water use is minimised

 

BASIX certificate submitted which includes requirements for water reuse.

Yes

Urban stormwater is treated is treated on site before being discharged to receiving waters

Refer to stormwater comments later in this report.

Yes

Flood management systems are integrated into site design

Suitable stormwater management systems are proposed to cater for any internal flooding of the basement parking area

Yes

4W Waste management

Waste storage facilities are designed to minimise impacts on the streetscape, building entry and amenity of residents.

 

A common waste storage area is proposed within the ground floor parking area in a location suitable for collection via a private contractor.

Yes

Domestic waste is minimised by providing safe and convenient source separation and recycling.

Collection from the proposed building can occur via private collection.

Yes

4X Building maintenance

Building design detail provides protection from weathering

 

The proposed design is considered to provide design solutions to be weather proof.

Yes

Systems and access enable ease of maintenance

Windows are considered to be able to be cleaned from inside.

Yes

Material selection reduces ongoing maintenance costs

 

The materials chosen for the proposed building are considered to be appropriate for the locality, robust and durable.

Yes

 

State Environmental Planning Policy No. 71 – Coastal Protection and Clause 5.5 of Port Macquarie-Hastings Local Environmental Plan 2011

The site is located within a coastal zone noting clause 4 of the SEPP.

In accordance with clause 5, this SEPP prevails over the Port Macquarie-Hastings LEP 2011 in the event of any inconsistency.

Having regard for clauses 2, 8 and 12 to 16 of the SEPP and clause 5.5 of the PMH LEP 2011, the proposed development will not result in any of the following:

a)         any restricted access (or opportunities for access) to the foreshore

b)         any adverse amenity impacts along the foreshore and on the scenic qualities of the coast;

c)         any adverse impacts on flora and fauna;

d)         the development being subject to any adverse coastal processes or hazards;

e)         any significant conflict between water and land based users of the area;

f)          any adverse impacts on any items of archaeological/heritage;

g)         reduction in the quality of the natural water bodies in the locality (due to effluent & stormwater disposal, construction impacts, landuse conflicts);

h)         adverse cumulative impacts on the environment;

i)          a form of development that is unsustainable in water and energy demands;

j)          development relying on flexible zone provisions. (refer to clause 5.3 of LEP 2011 - Development near zone boundaries unable to be undertaken when SEPP 71 applies).

The site is predominately cleared and located within an area zoned and substantially built out already with similar uses.

 

State Environmental Planning Policy (Building Sustainability Index: BASIX) 2004

A BASIX/universal certification has been submitted demonstrating that the proposal will comply with the requirements of the SEPP.  It is recommended that a condition be imposed to ensure that the commitments are incorporated into the development and certified at Occupation Certificate stage.

 

State Environmental Planning Policy (Infrastructure) 2007

Clause 101 refers to development with frontage to a classified road. In this case, the development has frontage to a classified road. Hastings River Drive is identified as MR600. The development is of a type that is sensitive to traffic noise or vehicle emissions and the applicant is to include measures to ameliorate potential traffic noise or vehicle emissions within the site of the development arising from the adjacent classified road. Overall, the noise issue is capable of being complied with and conditions have been imposed to address this issue at the construction certificate stage.

Clause 102 refers to noise and vibration impacts from a classified road on non-road development. The clause only applies to freeways, tollways and roads with an Annual Average Daily Traffic (AADT) of 40,000 vehicles. In this case, Hastings River Drive does not contain such traffic volumes and further consideration is not required.

The development does not trigger any of the traffic generating development thresholds of Clause 104.

Based on the above, the proposed development addresses relevant clauses in the SEPP and is unlikely to create any conflict in terms of traffic or noise.

 

Port Macquarie-Hastings Local Environmental Plan 2011

The proposal is consistent with the LEP having regard to the following:

·     In accordance with clause 2.2, the subject site is zoned B2 Local Centre. In accordance with clause 2.3(1) and the B2 zone landuse table, the proposed development for shop top housing development is a permissible landuse with consent.

The objectives of the B2 zone are as follows:

To provide a range of retail, business, entertainment and community uses that serve the needs of people who live in, work in and visit the local area.

To encourage employment opportunities in accessible locations.

To maximise public transport patronage and encourage walking and cycling.

To ensure that new developments make a positive contribution to the streetscape and contribute to a safe public environment.

In accordance with clause 2.3(2), the proposal is consistent with the zone objectives having regard to the following:

The proposal is a permissible landuse.

The proposal will provide a mixture of uses that will serve the area/locality.

Encourage employment opportunities via the ground floor retail.

By having reduced parking, the development will encourage a degree of walking and cycling within the area.

The design provides a fresh building to enhance the streetscape.

·     Clause 2.7, the demolition requires consent as it does not fit within the provisions of SEPP (Exempt and Complying) 2008.

·     Clause 4.3, the maximum overall height of the building above ground level (existing) is 12.925m which complies with the standard height limit of 14.5 m applying to the site.

·     Clause 5.9 - no listed trees in Development Control Plan 2013 are proposed to be removed.

·     Clause 4.4, the floor space ratio of the proposal is 1.21:1, which complies with the maximum 1.8:1 floor space ratio applying to the site.

·     Clause 5.10 – Heritage. The site does not contain but does adjoin a heritage item - see comments under Heritage heading later in this report.

·     Clause 7.7 – Airspace operations - condition proposed to cover height of crane approval (if utilised).

·     Clause 7.13, satisfactory arrangements are in place for provision of essential services including water supply, electricity supply, sewer infrastructure, stormwater drainage and suitable road access to service the development..

 

(ii)     Any draft instruments that apply to the site or are on exhibition:

 

No draft instruments apply to the site.

 

(iii)    any Development Control Plan in force:

 

Port Macquarie-Hastings Development Control Plan 2013

 

Residential Flat Development, Tourist and Visitor Accommodation and Mixed Use Development

DCP Objective

Development Provisions

Proposed

Complies

3.3.2.2

Satisfactory site analysis plan submitted.

Satisfactory site analysis plan submitted.

Yes

3.3.2.3

Statement addressing site attributes and constraints submitted.

Statement addressing site attributes and constraints submitted.

Yes

3.3.2.4

Streetscape and front setback:

·      Within 20% of the average setback of the adjoining buildings.

·      3m setback to all frontages if no adjoining development.

·      2m setback to secondary frontages.

·      Max. 9m setback for tourist development to allow for swimming pool.

Minimal setback proposed and the site is zoned B2 - Local Centre. Consistent with adjoining setbacks.

N/A – commercial zoned site

3.3.2.5

Balconies and building extrusions can encroach up to 600mm into setback.

N/A

N/A

Buildings generally aligned to street boundary.

Buildings generally aligned to street boundaries.

Yes

Primary openings aligned to street boundary or rear of site.

Primary openings aligned to street boundaries.

Yes

3.3.2.6

Side setbacks comply with Figure 3.3-1:

·      Min. Side setback 1.5m for 75% of building depth.

·      Windows on side walls min. 3m from side boundary.

·      3m minimum where adjacent to existing strata titled building.

Side setback to the south greater than 3m and 3m minimum to adjoining strata titled building.

Yes

Min. 6m rear setback (including sub basements)

1.486m to sub-basement- site adjoins an existing motel development. No balconies proposed in rear setback that allows for visual and acoustic privacy.

No, but acceptable.

3.3.2.11

Deep soil zones:

·      Extend the width of the site and have minimum depth of 6m.

·      Are contiguous across sites and within sites (see Fig 3.3-4).

228m² of deep soil zone or 21% of the site area is proposed. While not 6m in width, the dimensions are considered acceptable to meet the objectives of the DCP.

 

The location of the deep soil zone is satisfactory

No, but acceptable.

3.3.2.12

Deep soil zones accommodate existing advanced trees, and allow for advanced tree planting.

Deep soil zones can accommodate advanced tree planting.

Yes

3.3.2.13

Deep soil zones integrated with stormwater management measures.

Deep soil zones are capable to have integrated stormwater management measures.

Yes

3.3.2.14

Sunlight to the principal area of ground-level private open space of adjacent properties should not be reduced to less than 3 hours between 9.00am and 3.00pm on June 22.

Where existing overshadowing by buildings and fences is greater than this, sunlight should not be reduced by more than 20%.

Buildings should not reduce the sunlight available to the windows of living areas that face north in existing adjacent dwellings to less than the above specification.

Shadow diagrams have been submitted demonstrating compliance.

N/A

3.3.2.15

Internal clothes drying space provided (not mechanical).

No internal clothes drying space. Considered not mandatory.

N/A

Ceiling fans provided in preference to air conditioning.

N/A – refer BASIX.

N/A

Solar hot water systems (or equivalent technology) provided.

N/A – refer BASIX.

N/A

Photovoltaic arrays installed where practical.

N/A – refer BASIX.

N/A

3.3.2.16

Landscape plan provided including:

·      35% soft landscaping with minimum width of 3m.

·      Existing vegetation and proposed treatment.

·      Details of hard landscaping.

·      Location of communal recreational facilities.

·      Species not to obscure doors, paths, etc.

·      Street trees in accordance with Council’s list.

Satisfactory concept landscape plan submitted. Condition recommended to required detailed landscaping plan to be submitted prior to issue of a Construction Certificate.

Yes

3.3.2.17

Existing vegetation to be retained and nutrient-rich water prevented from entering native gardens.

No existing vegetation to be retained on-site.

N/A

3.3.2.18

Landscape plan to demonstrate how trees and vegetation contribute to energy efficiency and prevent winter shading on neighbouring properties.

Satisfactory concept landscaping plan submitted. Condition recommended to submit a detailed landscaping plan prior to the issue of a Construction Certificate.

Yes

3.3.2.19

Street trees in accordance with Council’s list.

A condition is recommended to require more details on landscaping prior to issue of a Construction Certificate

Yes - capable

3.3.2.22

Fencing or landscaping defines public/communal and private open space.

Fencing or landscaping defines public/communal and private open space.

Yes

3.3.2.23

Solid fences should be:

·      Max. 1.2m high,

·      Setback 1m,

·      Suitably landscaped,

·      Provide 3m x 3m splay.

N/A

N/A

Where front fences higher than 1.2m:

·      Max. 1.8m high,

·      Landscaped recesses for 50% of frontage, or length of fence not more than 6m or 50% of street frontage.

·      Min. 25% transparent,

·      3m x 3m splay for corner sites.

·      900mm x 900mm splay at vehicle driveways.

None proposed.

N/A

3.3.2.24

Fencing materials consistent with or complimentary to existing fencing in the street.

Older timber fencing.

N/A

3.3.2.25

Fences constructed of chain wire, solid timber or masonry and solid street not permitted, even if consistent with existing fencing in the locality.

N/A

N/A

3.3.2.26

Building to be designed so that:

·      Busy, noisy areas face the street.

·      Quiet areas face the side or rear of the lot.

·      Bedrooms have line of site separation of at least 3m from parking areas, streets and shared driveways.

Building designed so that:

·      Busy, noisy areas face the street.

·      Bedrooms have line of satisfactory site separation from parking areas, streets and shared driveways.

·      Acoustic certification will be required adjoining a classified road

Yes

Openings of adjacent dwellings separated by at least 6m.

Screen provided where appropriate

Yes

3.3.2.27

Building designed so noise transmission between apartments is minimised.

Building designed so noise transmission between apartments is minimised.

Yes

Uses are to be coupled internally and between apartments i.e. noisy internal and noisy external spaces should be placed together. (See Figure 3.3-6).

Uses are to be coupled internally and between apartments.

Yes

3.3.2.28

Development complies with AS/NZS2107:2000 Acoustic – Recommended design sound levels and reverberation times for building interiors for residential development.

Condition of consent to be applied - adjoining classified road.

Yes – capable subject to conditions

3.3.2.29

Impact of noise from key public places to be considered.

3.3.2.31

Developments to be designed in accordance with AS 1428.

Development capable of compliance with the design requirements of AS 1428. Specific details required to be submitted with the application for Construction Certificate

Yes

3.3.2.32

Barrier free access to at least 20% of dwellings provided.

Barrier free access available to all level 1 units.

Yes

3.3.2.33

Developments located close to open space, recreation, entertainment and employment.

The proposal is located on a site within close proximity to town centre.

Yes

Where LEP permits FSR > 1:1, FSR not less than 1:1 should be achieved.

FSR greater than 1:1 proposed.

Yes

3.3.2.34

Variety of types - studio, 1, 2, 3 and 3+ bedroom apartments

A variety of dwelling types are proposed

Yes

Studio and 1 bedroom apartments not > 20% of total number of apartments.

12 x 2 bedroom

 

Units 1-4,6,7,11,12 ( media room considered capable of use as a bedroom),13,15-17 ( 2 Bedroom) and 5 x 1 bedroom proposed- Units 5,8-10,14 (1 Bedroom). The 1 bedroom comprise 30% of total with a number of 1 bedroom units having media rooms that allow for flexibility in use. Considered that the mix is appropriate given location and demand for affordable housing/student accommodation.

No, but acceptable.

Mix of 1 and 3 bedroom apartments at ground level.

No ground level units – proposal is shop top housing, which requires shops/commercial at ground level.

N/A

3.3.2.35

Council’s Affordable Housing Strategy to be considered for residential flat buildings.

A mix of dwelling types are proposed.

Yes

3.3.2.36

Lift over-runs and plant integrated within roof structures.

Lift over-runs and plant integrated within roof structures.

Yes

Outdoor recreation areas on roof tops to be landscaped and incorporate shade structures and wind screens.

None proposed.

N/A

Outdoor roof areas oriented to the street.

None proposed.

N/A

Roof design to generate interesting skyline.

Roof design will generate an interesting skyline.

Yes

3.3.2.37

Facade composition should:

·      Have balance of horizontal and vertical elements.

·      Respond to environmental and energy needs.

·      Incorporate wind mitigation.

·      Reflect uses within the buildings.

·      Include combination of building elements.

Facade composition:

·      provides a balance of horizontal and vertical elements.

·      responds to environmental and energy needs.

·      incorporates wind mitigation.

·      reflect uses within the buildings.

·      includes a combination of building elements.

Yes

3.3.2.38

Building elements, materials and colours consistent or complimentary to those existing in the street.

Building elements, materials and colours consistent or complimentary to those existing in the street.

Yes

3.3.2.39

Entrances clearly identifiable from street level.

Entrances clearly identifiable from street level.

Yes

Entries provide clear transition between public street and shared private circulation spaces/apartments.

Entries provide clear transition between public street and shared private circulation spaces/apartments.

Yes

Entries provide clear line of sight between one circulation space and the next.

Entries provide clear line of sight between one circulation space and the next.

Yes

Entries avoid ambiguous and publicly accessible small spaces in entry areas.

Entries avoid ambiguous and publicly accessible small spaces in entry areas.

Yes

Entries sheltered and well lit.

Entries sheltered and well lit.

Yes

Entries and circulation spaces sized for movement of furniture.

Entries and circulation spaces sized for movement of furniture.

Yes

Lobby width minimum 2.5m wide and 3.0m high.

Lobby width > minimum 2.5m width however 2.8m height approximately. The compliant width caters for the minor variation to height. Objectives of DCP not compromised.

No, but acceptable.

Corridor lengths minimised and avoid tight corners.

Corridor lengths minimised and avoid tight corners.

Yes

Longer corridors articulated by:

·      Changing direction and width.

·      Utilising series of foyers.

·      Incorporating windows.

Longer corridors articulated by changing direction and windows are provided.

 

Yes

3.3.2.40

Minimum 1 balcony per apartment.

1 balcony per apartment.

Yes

Main balcony accessible from living area.

Main balcony accessible from living areas.

Yes

Balconies take advantage of favourable climatic conditions.

Balconies take advantage of favourable climatic conditions.

Yes

Balconies and balustrades balance privacy and views.

Balconies and balustrades balance privacy and views.

Yes

3.3.2.41

Balconies include sunscreens, pergolas, shutters and operable walls.

Balconies include screens, shutters and satisfactory shading.

Yes

Balconies recessed to create shadowing to facade.

Balconies recessed to create shadowing to facade.

Yes

Solid balustrades discouraged.

Solid balustrades are discouraged but may be considered where it is demonstrated that outlook and privacy is achieved and that there is sufficient articulation or visual interest in the building facade to accommodate the solid element. Solid balconies are not proposed in this instance.

Yes

Air conditioning units not visible from the street.

No air conditioning units proposed.

N/A

3.3.2.42

Secure open air clothes drying facilities that are:

·      easily accessible,

·      screened from public domain and communal spaces,

·      located with high degree of solar access.

No outdoor clothes drying facilities.

N/A

3.3.2.43

Mailboxes integrated into building design and sighted to ensure accessibility and security.

Mailboxes integrated into building design and sighted to ensure accessibility and security.

Yes

3.3.2.44

Public and private space clearly defined.

Public and private space clearly defined subject to more specific details on landscaping

Yes - capable

Entrances:

·      oriented to public street,

·      provide direct and well lit access between car parks, lift lobbies and unit entrances,

·      optimise security by grouping clusters (max. 8) around a common lobby

Entrances:

·      oriented to public street,

·      provision of direct and capability for well lit access between car parks, lift lobbies and unit entrances,

·      optimise security by grouping clusters around a common lobby

Yes

Surveillance facilitated by:

·      views over public space from living areas,

·      casual views of common internal areas,

·      provision of windows and balconies,

·      separate entries to ground level apartments.

Surveillance facilitated by:

·      views over public space from living areas,

·      casual views of common internal areas,

·      provision of windows and balconies,

·      separate entries to ground level apartments.

Yes

Concealment avoided by:

·      preventing dark or blind alcoves,

·      providing lighting in all common areas,

·      providing graded car parking illumination (greater at entrances).

Concealment avoided by:

·      preventing dark or blind alcoves,

·      providing lighting in all common areas,

 

Yes

Access to all parts of the building to be controlled.

Access to all parts of the building to be controlled.

Yes

3.3.2.45

Accessible storage provided for tenants in basement car park or garages.

Accessible storage provided for tenants in basement car park or garages.

Yes

One bike stowage space per dwelling provided.

Bicycle storage areas proposed in basement.

Yes

3.3.2.46

For developments of < 6 dwellings individual waste management permitted. Designated area to be provided for storage of bins:

·      not visible from street,

·      easily accessible,

·      not adjoining private or communal space, windows or clothes drying areas,

·      on hard stand area,

·      close to street and a tap for washing,

·      maintained free of pests.

Communal bulk waste facilities integrated into development and located at basement level.

 

Yes

Communal bulk waste required where:

·      > 6 dwellings, or

·      Number of bins wouldn’t fit in street frontage, or

·      Topography would make street collection difficult.

Communal bulk waste facilities integrated into development and located at basement level.

 

Yes

Communal bulk waste facilities integrated into development and located at ground or sub-basement level.

·      Not visible from street,

·      Easily accessible,

·      Can be serviced by collection vehicles,

·      Not adjoining private or communal space, windows or clothes drying areas,

·      Has water and drainage facilities for cleaning,

·      Maintained free of pests.

Communal bulk waste facilities integrated into development and located at basement level.

 

Yes

Evidence provided that site can be serviced by waste collection service.

Private waste collection proposed and required as a recommended condition of consent.

Yes

3.3.2.47

Common trenching of utility services where possible.

Services capable of being provided to proposal underground.

Yes

Above ground utility infrastructure integrated with building design.

Above ground utility infrastructure required to be integrated with building design. Substation location details are to be provided with the application for construction certificate.

Yes - capable

Site and individual units numbered.

Site and individual units can be appropriately numbered.

Yes - capable

Common aerials and satellite dishes provided.

Common aerials and satellite dishes can be appropriately provided.

Yes - capable

 

DCP 2013: General Provisions

DCP Objective

Development Provisions

Proposed

Complies

2.7.2.2

Design addresses generic principles of Crime Prevention Through Environmental Design guideline:

·      Casual surveillance and sightlines

·      Land use mix and activity generators

·      Definition of use and ownership

·      Lighting

·      Way finding

·      Predictable routes and entrapment locations

The proposed development will be unlikely to create any concealment/entrapment areas or crime spots that would result in any identifiable loss of safety or reduction of security in the immediate area. The increase in housing density will improve natural surveillance within the locality and openings from each dwelling overlook common and private areas.

Yes

2.3.3.1

Cut and fill 1.0m max. 1m outside the perimeter of the external building walls

Cut and fill 1.0m max. 1m outside the perimeter of the external building walls.

Yes

2.3.3.2

1m max. height retaining walls along road frontages

Approximate 1m max. height retaining walls along road frontages stepped to respond to topography.

Yes

Any retaining wall >1.0 in height to be certified by structural engineer

Condition recommended to require engineering certification for project.

Yes

Combination of retaining wall and front fence height

None proposed.

N/A

2.3.3.8 onwards

Removal of hollow bearing trees

No hollow bearing tree removal proposed.

N/A

2.6.3.1

Tree removal (3m or higher with 100mm diameter trunk and 3m outside dwelling footprint

One existing Black bean tree proposed to be removed.

Yes

2.4.3

Bushfire risk, Acid sulphate soils, Flooding, Contamination, Airspace protection, Noise and Stormwater

Refer to main body of report.

Yes

2.5.3.2

New accesses not permitted from arterial or distributor roads. Existing accesses rationalised or removed where practical

New access proposed from Hastings River Drive

Yes

Driveway crossing/s minimal in number and width including maximising street parking

Driveway crossing from Hastings River Drive maximising street parking.

Yes

2.5.3.3

Off-street parking in accordance with Table 2.5.1:

·   1 space = single dwelling (behind building line) and dual occupancy

·   Medium density – 1 per 1 or 2 bed dwelling or 1.5 per 3-4 bed dwelling + 1 visitor/4 dwellings

·   Commercial 1 space per 30m² or 1.5 spaces per office (whichever is greater)

Required:

17 x 1 & 2 bedroom units = 17 spaces.

Visitor parking 17/4 = 4.25 spaces.

Commercial 60m²/30m² = 2 spaces or 1 office x 1.5 spaces = 1.5 spaces. The 2 space requirement is the greater.

Total required = 17 + 4.25 + 2 = 23.25 spaces (rounds to 24)

(Note: the foyer area was not charged parking as it is considered ancillary to the residential units)

Proposed

Applicant proposes 22 spaces onsite. However, a space internally and externally will need to be converted to turning area, bringing the total number of spaces provided to 20 spaces. This represents a 4 space shortfall.

Contributions are to be levied to cover the shortfall. In particular, there are opportunities to use contributions in the area to improve/increase public parking in the area. Refer to comments on Parking and Manoeuvring later in this report for further justification.

No, but acceptable based on each dwelling/unit having a space onsite (which is the key issue) and contributions being levied on the remaining shortfall.

2.5.3.5

On-street parking permitted subject to justification

On-street parking not reliant upon for required parking provision.

N/A

2.5.3.7

Visitor parking to be easily accessible

Visitor parking easily accessible in basement parking area.

Yes

Parking in accordance with AS 2890.1

Parking and driveway widths on site can comply with relevant Australian Standards (AS 2890) and conditions have been imposed to reflect these requirements. Due to the type of development, car park circulation is required to enable vehicles to enter and exit the site in a forward manner.

Yes - capable

2.5.3.9

Bicycle and motorcycle parking considered and designed generally in accordance with the principles of AS2890.3

Bicycle parking/storage is available within the basement. Motorcycles could be parked in this space.

Yes

2.5.3.11

Section 94 contributions

Refer to main body of report.

Yes

2.5.3.12 and 2.5.3.13

Landscaping of parking areas

No specific landscaping of parking areas as basement parking proposed.

N/A

2.5.3.14

Sealed driveway surfaces unless justified

Sealed driveway surfaces required

Yes

2.5.3.15

Driveway grades for first 6m of ‘parking area’ shall be 5% grade

(Note AS/NZS 2890.1 permits steeper grades)

Parking and driveway widths on site can comply with relevant Australian Standards (AS 2890) and conditions have been imposed to reflect these requirements.

Yes

2.5.3.16

Transitional grades min. 2m length

2.5.3.17

Parking areas to be designed to avoid concentrations of water runoff on the surface.

The carparking areas are proposed within basement levels of the building. The access driveway is partly uncovered.

Yes

Vehicle washing facilities – grassed area etc available.

No vehicle washing facilities are proposed as only encourage by the DCP.

N/A

No direct discharge to K&G or swale drain

No direct discharge to K&G or swale drain

Yes

2.5.3.18

Car parking areas drained to swales, bio retention, rain gardens and infiltration areas

The carparking areas are proposed within basement levels of the building

N/A

DCP 2013: Westport Precinct

Development Provisions

Proposed

Complies

Residential flat buildings to have 24m frontage.

Dual frontages may accept an 18m frontage.

Frontage is 27.095m

The development is consistent with the relevant bulk and scale provisions of the LEP and DCP and as such the development potential is consistent with Councils vision for the development of the locality.

Yes

Development complies with:

-   Building height complies with LEP.

-   Setbacks and building alignments consistent with 4.2-4.

-   Controls on building height, commercial uses etc apply to Bridge, Gore and William Street.

Building height addressed in LEP section of this report.

Ceiling heights for residential first floor are 2.8m. The height is acceptable given the building use is unlikely to change in the near future.

Yes

Setbacks and building alignments to be consistent with Figures 4.2-5 & 6 or 3m where no setback shown.

Upper level to be setback.

Figure 4.2-5 allows a 0m setback to Hastings River Drive. Applicant has chosen a setback more conducive to the area and that required by section 3.3 of the DCP. Setback provides a good middle standard.

Yes

Side and rear setbacks to be:

-   3m from side boundaries.

-   6m from rear boundary.

-   South of Gordon Street 10m rear setback.

-   Party wall not appropriate.

The development is setback 3m from side boundaries.

 

It should be noted the property has a reduced rear setback but increased side setbacks provided for better acoustic outcomes for more sensitive receivers.

Yes.

Side and rear walls are to be articulated to provide privacy and separation with balconies of adjacent buildings by the following:

-   Up to 4 storeys or 12m = 6m habitable rooms/balconies and 3m non habitable.

-   Between 5 & 8 storeys or 25m = 9m habitable rooms/balconies and 4.5m non habitable.

Where separation does not exist, privacy screens or louvers may be utilised.

Where separation is compromised, the development contains no windows or has nominated privacy screens.

Yes

Open space areas are:

-   25% communal open space. Where 25% not possible due to constraints, 5m² per dwelling required.

-   2 hours sunlight for communal area between 9am and 3pm.

-   Communal areas may be reduced where development contributes to public area.

-   Rooftop communal setback from edges and not overlook.

Communal open space complies with 25% requirement. The communal area receives a suitable mixture of sun and shade.

Yes

Deep soil to site area provided as follows:

-   <650m² = 7%

-   650m² to 1500m² = 10%

-   >1500m² = 15%

Min 6m width unless a constrained site - see DCP for what constitutes constrained. Constrained sites need to be 3m.

10% paving allowed where tree growth can still occur.

Refer to comments in ADG assessment regarding deep soil zone areas. 

No, but acceptable.

Fences and retaining walls to comply with the following:

-   Within 1m of front boundary be max 1.2m high.

-   Variations allowed where ground floor level is higher than ground level.

-   Fences greater than 1.2m should be 50% transparent above the 1.2m height.

-   Fences should step down sloping sites.

None proposed.

N/A

Based on the above assessment, the variations proposed to the provisions of the DCP are considered acceptable and the relevant objectives have been satisfied.

Cumulatively, the variations do not amount to an adverse impact or a significance that would justify refusal of the application.

 

(iiia)  any planning agreement that has been entered into under Section 93f or any draft planning agreement that a developer has offered to enter into under Section 93f:

No planning agreement has been offered or entered into relating to the site.

 

iv)     any matters prescribed by the Regulations:

 

New South Wales Coastal Policy:

The proposed development is consistent with the objectives and strategic actions of this policy.

 

Demolition of buildings AS 2601:

Demolition of the existing building on the site is capable of compliance with this Australian Standard and is recommended to be conditioned.

 

v)      any coastal zone management plan (within the meaning of the Coastal Protection Act 1979), that apply to the land to which the development application relates:

·     No Coastal Zone Management Plan applies to the subject site.

 

(b)     The likely impacts of that development, including environmental impacts on both the natural and built environments, social and economic impacts in the locality:

 

The site has a general easterly street frontage orientation to Hastings River Drive.

Adjoining the site to the north is an existing residential development.       

Adjoining the site to the east are existing commercial development.

Adjoining the site to the south is an existing heritage listed Backpackers Establishment.    

Adjoining the site to the west is an existing motel.   

The proposal will be unlikely to have any adverse impacts to existing adjoining properties and satisfactorily addresses the public domain.

The proposal is considered to be consistent with other commercial/residential development in the locality and adequately addresses planning controls for the area.

The proposal does not have a significant adverse impact on existing view sharing.

The proposal does not have significant adverse lighting impacts.

There are no significant adverse privacy impacts.  Adequate building separation and tenancy is proposed/existing.

There is no adverse overshadowing impacts. The proposal does not prevent adjoining properties from receiving 3 hours of sunlight to private open space and primary living areas on 21 June.

 

Roads

The site is bordered to the east by Hastings River Drive, a dual carriageway arterial road within a road reserve 30m wide. Hastings River Drive is owned and maintained by Council, with the RMS having a concurrence role as it is a regional classified road – see the RMS heading below.

An upgrade of Hastings River Drive near the site was completed by Council in early 2016 providing a number of improvements, including:

·    The northbound lane fronting the site now has a median island, forcing traffic access to the site to be left in / left out only. A roundabout 120m to the north along Hastings River Drive facilitates a safer turning movement for traffic heading in other directions.

·    Concrete footpath was constructed along the frontage of the site. No further footpath augmentation is considered necessary in connection with this proposal.

·    A kerbside parking lane was upgraded with new concrete pavement, upright (SA type) kerb, and a dish drain and stormwater pit.

 

Traffic and Transport

The proposal has previously been presented to Council in a similar form under pre-lodgement meetings 2016/69 and 2017/51.

 

Previous DA 2004/819 for a 4-storey residential flat building also applies to the land, but as the development has not been completed, no credit in regard to parking or traffic generation has been assessed.

 

The site is currently occupied by a dwelling with a single vehicular access driveway to the road network. An estimate of existing vehicular trips would be in the order of 7-9 trips per day on average.

 

The RMS Guide to Traffic Generating Development (2002) provides a trip generation rate for Residential Flat Buildings of 4-5 average trips per day, which is expected to be appropriate for this proposal given the site’s close proximity to the CBD. For the proposed 17 units (counting units 11b and 12b as separate occupancies and generators), this equates to around 90 trips per day, or an increase of 83 trips compared with the existing dwelling. 83 trips per day would generally amount to around 9 trips during each of the AM and PM peak (commuter) periods, assuming a peak factor of 0.1 which is typical.

 

Also provided in the RMS Guide is a peak hourly rate of 10 trips per 100sqm of office GFA, which for the 22sqm of body corporate floor area is 2.2 trips (i.e. per AM and PM commuter peak period), noting that this office floor area may later be used by a different type of business without the need for a change of use DA. 22 daily trips is expected to be conservative (high).

 

A traffic generation estimate for the retail floor area (60sqm) is less certain until the nature of the tenant business is known, but a simple rate of 15 trips per 100sqm is likely to be adequate with reference to the RMS Guide. Thus 10 trips per peak hour or 100 trips per day is expected to be a conservative (high) estimate.

 

The total increase in trip generation for this development is therefore expected to be in the order of 21 during each AM and PM peak hour and 205 trips per day. The site’s location on Hastings River Drive (a four lane arterial road) and proximity to the Oxley Highway means the local road network will cater for the proposed minor increase with no significant impacts.

 

Roads and Maritime Services (RMS)

RMS referral is not required at the DA stage as none of the provisions of Schedule 3 of the SEPP (Infrastructure) 2007 are triggered by the development.

Details of any works within the Hastings River Drive road reserve will need to be referred to the RMS under s139 of the Roads Act as it is a designated Regional Road (linking the Oxley Hwy in the west to the Port Macquarie town centre, east). Works are expected to be minor (not affecting traffic lanes).

 

Site Frontage & Access

Vehicle access to the site is proposed though one access driveway. AS 2890.1 clause 3.2.2 stipulates that a driveway for this type of development must be provided with 5.5m width for at least the first 6m into the site, given the arterial road and blind corner proposed at the entrance to the carpark. This will ensure that two cars may pass without one being forced to wait within the road reserve, potentially impeding traffic flows, which is a key concern as the site is so close to the major intersection of Oxley Highway and Hastings River Drive.

 

Consent conditions will require the Roads Act (s138) construction details to reflect this. Otherwise the proposed access can comply with Council AUSPEC and Australian Standards, subject to detailed design.

 

Parking and Manoeuvring

While there is adequate area for three (3) parking spaces to be located outside the gated car park, one of these spaces is required to provide a dedicated turnaround area (no parking) to enable vehicles which enter the site to leave in a forwards-only direction if the gate is not opened (e.g. if they are visiting). Forwards-only exit is a requirement of AS 2890.1 and is particularly important for this site, given the high volume of traffic on Hastings River Drive and proximity to the intersection, increasing the risk of a collision if vehicles were required to reverse out of the site. A condition of consent has been recommended to this effect.

A dedicated turning bay will also be required within the gated car park area as it now contains a public/visitor parking component. Overall, site plans show adequate area is available for the internal access aisles and parking bays to comply with AS 2890.1 and conditions have been imposed to reflect these requirements.

 

Parking and access to and from has been designed to comply with AS/NZS 2890.In this regard the AS design requirements which are applicable to Category 1A parking facility have been applied to the proposed development.

 

It is noted that the Category 1 provisions of AS 2890.1 provide for a proposed access driveway width of 3m under certain circumstances. In this regard, the proposed development will generate peak hour traffic movements which will be well less than the 30-movement trigger, which is relevant to the provision of a minimum 5.5m wide two car driveway. The suitability of the proposed single width driveway is further supported by the existing on-street parking bay which is immediately adjacent to the subject site.

 

The design of the proposed development provides for forwards vehicle movements to and from the subject development. It is proposed with respect to the proposed commercial floor space within the proposed development. Reference to Table 2.5.1 of PMHC DCP 2013 indicates that stacked parking is not counted towards compliance unless staff parking spaces are separately identified and delineated (Clause 2.5.3.7(e) of the DCP). The development now provides that the commercial car parking spaces will be separately identified and delineated and as such the tandem arrangement is suitable for use in relation to the commercial floor space.

 

In response to the issues raised at the DAP meeting, the design of the subject development has been amended as follows;

·    22 spaces proposed, albeit 2 spaces will be lost to turning spaces, bringing the total to 20 spaces. Council controls require 24 spaces, which results in a shortfall in parking of 4 spaces.

·    The design of the ground floor car parking area has been modified so as to provide 19 spaces within the building. One of the 19 spaces will be lost to a turning space, leaving 18 spaces. The 18 spaces are sufficient to meet all residential requirements and part of the visitor car parking needs. 

·    The floor area of the ground floor commercial area has been reduced to a maximum of 60m² thereby reducing the associated car parking demand to 2 spaces.

·    The driveway area has been redesigned so as to provide for two (2) stacked car parking spaces, which will meet the parking demand associated with the commercial floor space. The ground floor office area has been deleted with this area being utilized in conjunction with the residential use of the building (resident foyer). Whilst not ideal to utilise stack parking - use for commercial arrangements is considered acceptable for staff parking only.

·    The provision of the additional car parking spaces on site is difficult to achieve and be financially viable given the spatial dimensions of the subject site.

·    The location of the site to a busy intersection is likely to deter some visitors from accessing the site, which reduces demand.

·    There is a designated ‘on-street’ car parking area directly in front of the building providing for two (2) spaces.

·    A precinct parking plan has been submitted by the applicant demonstrating significant on street car parking opportunities are available within 150m of the proposed development. Bridge Street in particular provides for significant ‘on street’ parking due to its width and the low levels of usage of this road infrastructure. There is also a public car park located between Gordon and Bridge Street, within a walkable 215m.

·    Safe pedestrian access is available throughout the locality, including to and from nearby car parks, residential and commercial developments etc. This overall accessibility is likely to reduce demand for cars and onsite parking.

·    Contributions can be levied for the shortfall, which can be utilised to upgrade the existing public parking in the area.

 

It is considered that the development is appropriate in the area and that the combination of close proximity to all services by foot and the availability of car parking in the immediate area allows for concessions on site. The development is also consistent with encouraging higher density development that does not necessarily require residents to be reliant on vehicle usage.

 

Water Supply Connection

Council records indicate that the existing development site has a 20mm metered water service from the 150mm AC water main on the same side of Gordon Street. Final water service sizing will need to be determined by a hydraulic consultant to suit the domestic and commercial components of the development, as well as fire service and backflow protection requirements. The dwellings and commercial premises must be individually metered for water.

Detailed plans will be required to be submitted for assessment with the S.68 application.

 

Sewer Connection

If the proposed car park extension will encompass the existing sewer manhole then the manhole lid and surround will have to be replaced with heavy duty components.

 

As the dwellings are to be Strata Titled, a private sewer system can be adopted, connected.

 

The hydraulic designer is to confer with Council sewer section prior to submitting sewer design plans.

 

Detailed plans will be required to be submitted for assessment with the S.68 application.

 

Stormwater

The site naturally grades westwards towards the street and a stormwater pit was recently constructed adjacent to the site as part of the Hastings River Drive upgrade by Council. The legal point of discharge for the proposed development is defined as a direct connection to Council’s stormwater network. A detailed site stormwater management plan will be required to be submitted for assessment with the S.68 application and prior to the issue of a Construction Certificate.

 

In accordance with Councils AUSPEC requirements, on site stormwater detention facilities must also be incorporated into the stormwater drainage plan to ensure that post-development peak flows from the site will not exceed pre-development flows. There is ample room within the site beneath paved surfaces to accommodate storage volume. Refer to relevant conditions of consent.

 

Other Utilities

Telecommunication and electricity services are available to the site.

Evidence of satisfactory arrangements with the relevant utility authorities for provision to each proposed lot will be required prior to Occupation Certificate approval for the separate domiciles.

 

Heritage

The adjoining property contains a heritage listed item. Following a site inspection Councils’ Heritage Advisor has made the following comments:

 

The design, whilst simple in overall planning adopts a complexity of form combining a number of materials and devices that detract from the potential simplicity and cohesiveness of the building.

 

A green wall is proposed over two levels on the Northern elevation facing the adjacent multi-unit dwelling. The southern elevation facing Elsinore is broken up by the central stairway and its louvred treatment and the flanking stairs on the east and west with similar external treatment.

 

External materials include glass shopfronts, Designer Series bricks, rendered brick, weatherboards, horizontal louvres and vertical louvres as well as a finish to the upper floor which is not stipulated by appears to be terracade or similar, but is nominated in the SOHI as dark timber. The elevations are very busy in this way with their composite finishes especially alongside the heritage building.

 

The large Black Bean tree is being lost as a result of the proposal.

 

The set back from the heritage item is sufficient. The overall form of the building is considered to be reasonably well modulated and articulated, however a level of complexity has been introduced which is considered to be unnecessary.

 

It is accepted that the use of weatherboard is referential, however there needs to be further consideration of consistency of finish to simplify the elevational treatment.

 

A colour palette and finishes is to be submitted to the PCA with the application for the Construction Certificate that incorporates a simplified finishes proposal.

 

The heritage item is isolated from other significant buildings and the precinct is a mix of 1960’s and 70s construction. The proposed development replaces a red brick dwelling and is considered to establish a future desired character for the area. A condition of consent is proposed to submit a colour and material palette in accordance with the recommendations from the Heritage advisor.

 

Other land resources

The site is within an established urban context and will not sterilise any significant mineral or agricultural resource.

 

Water cycle

The proposed development will be unlikely to have any adverse impacts on water resources and the water cycle.

 

Soils

The proposed development will be unlikely to have any adverse impacts on soils in terms of quality, erosion, stability and/or productivity subject to a standard condition requiring erosion and sediment controls to be in place prior to and during construction.

 

Air and microclimate

The construction and/or operations of the proposed development will be unlikely to result in any adverse impacts on the existing air quality or result in any pollution. Standard precautionary site management condition recommended.

 

Flora and fauna

Construction of the proposed development will not require any removal/clearing of any significant vegetation and therefore will be unlikely to have any significant adverse impacts on biodiversity or threatened species of flora and fauna.  Section 5A of the Act is considered to be satisfied

 

Waste

Satisfactory arrangements are in place for proposed storage and collection of waste and recyclables. No adverse impacts anticipated. Standard precautionary site management condition recommended.

 

Energy

The proposal includes measures to address energy efficiency and will be required to comply with the requirements of BASIX or Section J of the Building Code of Australia. No adverse impacts anticipated.

 

Noise and vibration

No adverse impacts anticipated. Condition recommended to restrict construction to standard construction hours.

Dwellings will be conditioned to be designed to address noise impacts from Hastings River Drive.

 

Bushfire

The site is not identified as being bushfire prone.

 

Safety, security and crime prevention

The proposed development will be unlikely to create any concealment/entrapment areas or crime spots that would result in any identifiable loss of safety or reduction of security in the immediate area. The increase in housing density will improve natural surveillance within the locality and openings from each dwelling overlook common and private areas.

 

Social impacts in the locality

Given the nature of the proposed development and its’ location the proposal is unlikely to result in any adverse social impacts.

 

Economic impact in the locality

No adverse impacts. A likely positive impact is that the development will maintain employment in the construction industry, which will lead to flow impacts such as expenditure in the area.

 

Site design and internal design

The proposed development design satisfactorily responds to the site attributes and will fit into the locality. No adverse impacts likely.

 

Construction

No potential adverse impacts identified to neighbouring properties with the construction of the proposal.

 

Cumulative Impacts

The proposed development is not expected to have any adverse cumulative impacts on the natural or built environment or the social and economic attributes of the locality.

 

(c)     The suitability of the site for the development:

 

The proposal will fit into the locality and the site attributes are conducive to the proposed development.

 

(d)     Any submissions made in accordance with this Act or the Regulations:

 

Two (2) written submissions have been received following public exhibition of the application.

 

Key issues raised in the submissions received and comments in response to these issues are provided as follows:

 

Submission Issue/Summary

Planning Comment/Response

Heritage Impact on adjoining heritage listed building and removal of significant Queensland Blackbean Tree

The site has been inspected by Council’s Heritage advisor who has indicated a general acceptance of the proposal. The tree is no longer within the curtilage of the heritage item and so is difficult to retain.

Proposal out of scale with heritage listed building

The proposal has been provided with reasonable setbacks to the heritage item with the driveway access located adjoining the building. The proposal is considered acceptable.

Overshadowing

Shadow diagrams have been submitted which indicate compliance with the required hours of solar access to the living areas. The building has been designed to allow reasonable solar access.

Traffic impact and insufficient parking

See comments above in this report on Traffic and Transport, Parking and Manoeuvring and also DCP 2013 parking calculations. Overall, no adverse traffic or parking issues will occur. The applicant will also be required to pay additional s94 contribution in lieu of the 4 space shortfall.

Insufficient bin storage

A private bin collection service will be required.

Noise and vibration during construction

Standard conditions of consent will be applied to manage construction noise.

Noise and privacy due to increase in pedestrian activity

It is considered that the increase in activity will provide positive benefits to enhance the area and increase safety and security. It is not anticipated that the development will unduly create an unacceptable noise impact.

Deep soil zone

The site has proposed a number of areas suitable for planting of medium sized trees and the proposal complies with the required setbacks.

Privacy into adjoining communal areas

The development has been designed to consider privacy with provision of screens and walls to address immediate overlooking. The lower two levels have been provided with a natural screen and planting proposals. It is considered the upper levels will be higher and overlook the roof areas and the pool area is exposed to general overlooking by the multiple existing units.

Overdevelopment of the site

The application complies with the required Floor Space Ratio requirements of the site and addresses the future desired character of the precinct.

(e)     The Public Interest:

The proposed development will be in the wider public interest with provision of appropriate additional housing.

The proposed development satisfies relevant planning controls and is unlikely to impact on the wider public interest.

 

 

4.       DEVELOPMENT CONTRIBUTIONS APPLICABLE

 

·    Development contributions will be required towards augmentation of town water supply and sewerage system head works under Section 64 of the Local Government Act 1993.

·    Development contributions will be required under Section 94 of the Environmental Planning and Assessment Act 1979 towards parking, roads, open space, community cultural services, emergency services and administration buildings.

 

5.       CONCLUSION

 

The application has been assessed in accordance with Section 79C of the Environmental Planning and Assessment Act 1979.

 

Issues raised during assessment and public exhibition of the application have been considered in the assessment of the application. Where relevant, conditions have been recommended to manage the impacts attributed to these issues.

 

The site is suitable for the proposed development, is not contrary to the public's interest and will not have a significant adverse social, environmental or economic impact. It is recommended that the application be approved, subject to the recommended conditions of consent provided in the attachment section of this report.

 

Attachments

 

1View. DA2017 - 780.1 Plans.

2View. DA2017 - 780.1 Amended Ground Floor Plan

3View. DA2017 - 780.1 Amended Site Plan

4View. DA2017- 780.1 Precinct Parking

5View. DA2017 - 780.1 Recommended DA Conditons

6View. DA2017 - 780.1 Submission - McVeagh

7View. DA2017 - 780.1 Submission - Vogel

 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


 


 


 


 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


 


 


 


 


 


 


 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


AGENDA                                              Development Assessment Panel      09/05/2018

 

 

Item:          06

 

Subject:     Section 4.55 Modification DA2010 - 577.4 - Modification To Subdivision Lot Layout Including Addition Of One (1) Torrens Title Lot - Lot 2 DP 1231106, No. 72 Lorne Road, Kendall

Report Author: Patrick Galbraith-Robertson

 

 

 

Applicant:               Jojeni Investments Pty Ltd CARE GEM Planning Projects

Owner:                    Jojeni Investments Pty Ltd

Estimated Cost:     N/A

Parcel no:               66659

Alignment with Delivery Program

4.3.1  Undertake transparent and efficient development assessment in accordance with relevant legislation.

 

 

 

RECOMMENDATION

That Section 4.55 modification to DA 2010 - 577 for a modification to subdivision layout including addition of one (1) torrens title lot at Lot 2, DP 1231106, No. 72 Lorne Road, Kendall, be determined by granting the modified consent subject to the recommended conditions.

 

 

Executive Summary

 

This report considers a Section 4.55(2) modification of consent application at the subject site and provides an assessment of the application in accordance with the Environmental Planning and Assessment Act 1979.

 

Being a Section 4.55 modification, the modified proposal has only been assessed against the legislation and related planning guidelines in place at the time of the original assessment.

 

Following exhibition of the application, one (1) submission has been received.

 

The proposal has been amended during the assessment of the application.

 

This DA has been previously considered by the Development Assessment Panel on 26 April 2018 where the following resolution was made:

 

Defer determination of the Section 4.55 modification to DA 2010 – 577, subject to the submission of stormwater management detail being provided to the Development Assessment Panel. The information is to show how stormwater impacts on the new Lot 8 and also whether the new Lot 8 impacts on the ability to deal with stormwater management for the overall subdivision.

 

The Applicant has subsequently provided additional specialist stormwater information to address the Panel’s concerns which are attached to this report. Additional commentary is also provided later in this updated report.

 

1.       BACKGROUND

 

Existing sites features and surrounding development

 

The site has an area of 13.11 hectares.

 

The section of the site to which the modification application relates to is zoned 1(r1) Rural Residential in accordance with the Hastings Local Environmental Plan 2001 (as in force at the time), as shown in the following zoning plan:

 

 

The existing subdivision pattern and location of existing development within the locality is shown in the following aerial photograph:

 

 

2.       DESCRIPTION OF DEVELOPMENT

 

The current approved development, as modified is for a staged 13 lot subdivision. A copy of the current approved modified plans are shown below:

 

 

 

The development is physically commenced with Lots 1 and 2 already created/released.

 

Key aspects of the modification proposal include the following:

 

·    Modify previous approved staged subdivision to realign boundaries and add an additional one (1) allotment at the northern end of the subdivision (where Lot 9 and 10 are shown above). This will increase the total lot numbers from 13 to 14.

 

The proposal has been also amended during the assessment of the application to incorporate compliant cul-de-sac sections of road with a 12m radius. This has also resulted in minor changes to boundaries to retain compliant minimum 1 hectare lot sizes.

 

Refer to attachments at the end of this report.

 

Application Chronology

 

·    7 December 2017 – Modification application lodged with Council

·    13 December 2017 – Referral of modification application to NSW Rural Fire Service

·    18 December 2017 to 12 January 2018 - Neighbour notification of proposal

·    12 February 2018 – Additional information requested – submission issues and on-site sewage capacity

·    19 February 2018 – NSW Rural Fire Service issued Bushfire Safety Authority

·    20 February 2018 – Clarification sought on cul-de-sac radius required by NSW Rural Fire Service

·    13 March 2018 – Confirmation of 12m radius on cul-de-sac required

·    16 March 2018 – Updated on-site sewage management report received

·    24 March 2018 – Updated on-site sewage management report forwarded to submitter for consideration

·    12 April 2018 – Amended plans received including enlarging radius of cul-de-sac head to comply with 12m radius required by the NSW Rural Fire Service

·    26 April 2018 – Consideration of DA by the Development Assessment Panel. Resolution to defer consideration of DA until further information is received. Revised information since received.

 

3.       STATUTORY ASSESSMENT

 

Section 4.15(2) Matters for Consideration

 

In determining the application, Council is required to take into consideration the following matters as are relevant to the development that apply to the land to which the development application relates:

 

(a) Is the proposal substantially the same?

 

Section 4.55 of the Environmental Planning and Assessment Act 1979 enables the modification of consents and categorises modifications into three categories - S.4.55(1) for modifications involving minor error, mis-description or miscalculation; S.4.55(1A) for modifications involving minimal environmental impact; and S.4.55(2) for other modifications. Each type of modification must be considered as being substantially the same to that which was originally consented to.

 

The subject application is being considered under the provisions of Section 4.55(2).

 

The Applicant has submitted the following details to justify that the proposal is substantially the same development:

·    The proposal seeks to modify minor aspects of the approved subdivision but does not alter the servicing capacity, the environmental principles nor the character of the approved development.

·    One additional x 1 ha allotment will result in the northern location and it does alter the intersection location or road access principles.

·    The modified proposal conforms to the requirements of existing Rural Fire Service S100B authority.

 

Having regard to the above, the proposed modification is not considered to alter the fundamental essence of the original development and is considered to be substantially the same to the original development and therefore within the scope of a modification application.

 

(b)  Are there any condition(s) of consent imposed by a Minister, government or public authority that require modification?

 

The application has been referred to the NSW Rural Fire Service (RFS). The RFS have reviewed the proposal and issued an amended Bushfire Safety Authority for the modified proposal. The Applicant has also submitted amended plans to provide details of the required minimum 12m radius cul-de-sacs required by the RFS.

(c)  Does the application require notification/advertising in accordance with the regulations and/or any Development Control Plan?

 

Neighbour notification has been undertaken in accordance with the DCP.

 

(d)  Any submissions made concerning the modification?

 

One (1) written submission has been received following public exhibition via neighbour notification of the application.

 

The issues raised in the submission received have been forwarded to the Applicant during the assessment of the application.

 

Key issues raised in the submission received and comments in response to the issues are provided as follows:

 

Submission Issue/Summary

Planning Comment/Response

Concerns relate to the onsite sewage management of this modification referring specifically to the three blocks 9, 10 and 11 having common boundary with our property Lot 65.

 

The Applicant has submitted additional specialist information during the assessment of the application to address site specific on-site sewage management for the proposed additional lot and boundary reconfiguration. A copy of this report is attached.

The additional report submitted has been assessed by Council Staff as being satisfactory.

The latest proposed modification of the subject site could significantly increase environmental effects such as potential for seepage/runoff to our creek immediately adjacent to our South boundary, any contemplation that another method of disposal of septic waste, secondary or not, within the 40 metre zone would mean leakage into our creek.

Concerns of how overland stormwater runoff will be channelled away from this development considering the slope characteristics of the site and in particular regard to the proposed roads 1 and 2.

Refer to the comments provided later in this report to address stormwater.

 

(3)  Any matters referred to in section 4.15/79C (1) relevant to the modification?

 

Taking into consideration of the reasons for approval of the original development, the following areas of the original assessment impacted by the changes or with revised comments are addressed below:

 

North Coast Regional Environmental Plan

 

In accordance with clause 2, the modified proposal remains consistent with the aims of this REP.

 

In accordance with clause 12, the modified proposal is unlikely to adversely impact on the use of any nearby adjoining or adjacent agricultural land and the proposed subdivision will be unlikely to result in a significant loss of prime crop or pasture land. In particular, given the section of the site had a previous zoning change (that has occurred) to become 1(r1) now known as R5 Large Lot residential.

 

In accordance with clause 43, the modified proposal remains satisfactory with regard to:

·    the density of the proposed lots has been maximised without adversely affecting the environmental features of the land,

·    the proposed road widths are not excessive for the function of the road, and

 

Port Macquarie-Hastings Local Environmental Plan 2001

 

The above LEP was in place at the original time of assessment and determination of this DA.

 

In accordance with clause 9, the subject site (in total) is zoned part 1(a1) Rural, 1(a3) Rural – Agricultural Protection, 1(r1) Rural Residential and 7(h) Environment Protection - Habitat. The modification to the remaining subdivision lots to be constructed and released are entirely within the 1(r1) zoned section of the site.

 

The objectives of the 1(r1) zone are as follows:

 

Zone 1 (r1) Rural Residential

Zone objectives

(a) To enable the development of land within this zone for rural residential purposes.

(b) To enable appropriate development where allowed with consent.

 

The proposal is consistent with the zone objectives, particularly as the proposal will not result in any unnecessary land fragmentation and based upon appropriate conditions recommending fencing off the 7(h) zoned land.

 

In accordance with clause 13, satisfactory arrangements are available for water supply and facilities for removal/disposal of on-site sewage and drainage to the proposal (as amended).

 

Note that Stage 1 will not require/propose extension of water supply servicing to proposed Lot 2 within Stage 1.

 

In accordance with clause 17, the Lot sizes proposed within the 1(r1) zoned part of the site remain compliant with the minimum 1 hectare land area requirement, will provide for satisfactory land area to enable on-site disposal of effluent and bushfire risk has been satisfactorily addressed.

 

The requirements of this LEP are therefore satisfied.

 

Development Control Plan 17 – Subdivision Code

 

The modified proposal remains to comply with all applicable development provisions relating to recommended lot servicing and design requirements of this DCP.

 

 

 

Context and setting

The modified proposal will be unlikely to have any adverse impacts to existing adjoining properties and satisfactorily addresses the public domain.

 

The desired character for the site has been set by the change in zoning to rural residential and with the 1 hectare lot size adopted. The modified proposal is considered to be consistent with the desired character for future and existing rural and rural residential development in the locality and adequately addresses planning controls for the area.

 

There are no identifiable adverse impacts to neighbouring properties.

 

Access, transport and traffic

The subject property has frontage to Lorne Rd which is a dedicated bitumen sealed rural road maintained by Council. Lorne Rd carriageway is approximately six (6) metres wide.

 

The proposed subdivision has already been approved to produce 91 additional daily trips, the addition of one extra allotment will not have any significant effect on the proposed development or the surrounding road network.

 

On-site sewage management

The Applicant has submitted additional specialist information during the assessment of the application to address site specific on-site sewage management for the proposed additional lot and boundary reconfiguration. A copy of this report is attached. The additional report submitted has been assessed as being satisfactory.

 

Stormwater

The proposal does not include a stormwater management plan and instead notes that the subdivision will be constructed in accordance with the plan prepared as part of the rezoning of the site. The original assessment raised no objections towards this approach in principal noting that detailed design and remodelling of all elements will be required to be undertaken prior to the issue of a Construction Certificate.

 

There is a Stormwater Management Plan dated March 2007, which includes the use of infiltration trenched/basins and buffer strips on private property, appropriate easements and positive covenants/restrictions as to user will be required to be placed on relevant lots at time of subdivision and maintenance access/rights are provided.

 

Such instruments will also be required to be created over flowpaths through the properties to both enable future access and to alert purchasers/landowners to their rights and obligations with respect to the flow of waters through the site.

 

There is a condition already imposed to create a positive covenant for maintenance of the existing overland flowpath over the site.

 

Stormwater analysis has been submitted demonstrating that the pre development flows within the existing watercourse are 5.81 cu.m/s with a water level of 11.37m AHD adjacent to Proposed lot 7. The post development flow will be 5.83 cu.m/s within the realigned overland flowpath with the water level maintained at 11.37m adjacent to Lot 7. The depth of flow within this flowpath is to remain at 370mm as per pre development.

 

The proposed building platforms on proposed lots 8 & 9 are well in excess of any required freeboard and an appropriate restriction has been conditioned to ensure any future building on Proposed lot 7 is constructed an appropriate level.

 

Based on the above, the proposed development will create no adverse impacts on stormwater and visa versa.

 

Water

Water Supply for this modified development can remain to be provided from the 100mm AC water main on the same side of Lorne Road.

 

Fire service coverage to the building envelope of each lot to AS 2419 is to be provided wherever there is reasonable prospect of coverage from a street hydrant.

 

The subdivision plans with suitable Section 88B instruments are to show building envelopes that can be covered by street hydrants to AS 2419. This information is to be shown on the engineering plans for assessment by Water Supply Section before linen release but is deemed capable of complying.

 

Water cycle

The proposed development will be unlikely to have any adverse impacts on water resources and the water cycle.

 

Bushfire

The site is identified as being bushfire prone. The Applicant has submitted a revised bushfire report, which was forwarded to the NSW Rural Fire Service. The NSW Rural Fire Service have assessed the application and issued an amended Bushfire Safety Authority for the modified development. A copy is attached to this report.

 

The proposal has been also amended during the assessment of the application to incorporate compliant cul-de-sac sections of road with a 12m radius. Section H of the development consent is recommended to be deleted and replaced with a more current standardised condition to reference the amended bushfire authority.

 

4.       DEVELOPMENT CONTRIBUTIONS APPLICABLE

 

·    Additional development contributions for the additional lot will be required towards augmentation of local water supply head works under Section 64 of the Local Government Act 1993.

·    Additional development contributions for the additional lot will be required under Section 94 of the Environmental Planning and Assessment Act 1979 towards roads, open space, community cultural services, emergency services and administration buildings.

 

5.       CONCLUSION

 

The application has been assessed in accordance with Section 4.55 of the Environmental Planning and Assessment Act 1979.

 

Issues raised during assessment and public exhibition of the application have been considered in the assessment of the application.

 

The site is suitable for the proposed modified development, is not contrary to the public's interest and will not have a significant adverse social, environmental or economic impact. It is recommended that the application be approved, subject to the recommended conditions of consent provided in the attachment section of this report.

 

Attachments

 

1View. DA2010 - 577.4 Plans

2View. DA2010 - 577.4 Stormwater Report

3View. DA2010- 577.4 Stormwater Plan

4View. DA2010 - 577.4 Buffers Sewage Management Onsite

5View. DA2010 - 577.4 Onsite Report

6View. DA2010 - 577.4 Recommended Amended Conditions.

7View. DA2010 - 577.4 NSW Rural Fire Service  Recommendations

8View. DA2010 - 577.4 Submission - Guy

 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


 


 


 


 


 


 


 


 


 


 


 


 


  ATTACHMENT

Development Assessment Panel

09/05/2018

 


 


  ATTACHMENT